Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2024-01-29-57
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Verification
Type of Material: SMTL TM10 - Wire Rope Choker
Sample Taken Date: 01/29/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/22/2024
The quantity of what the sample constitutes: 5
A brief description of the sample: 5/16" 3/8" 1/2" Wire Rope
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: cableco
DIME Test ID: 2024-01-29-57-1
Test Method: ASTM A931-18: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 04/23/2024
Date Tested: 04/23/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Broke in Wire
Test Result Compliance:
Additional Comments When Verified:
|
Temperature
|
72 F
|
|
UTM
|
67kip
|
|
Specimen Identification
|
Wire Rope
|
|
Peak Load
|
11819.1
|
|
Operator
|
5/16 yellow
|
|
Location of Failure
|
Below Crimp
|
DIME Test ID: 2024-01-29-57-2
Test Method: ASTM A931-18: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 04/23/2024
Date Tested: 04/23/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Broke in Wire Right at Crimp
Test Result Compliance:
Additional Comments When Verified:
|
Temperature
|
72 F
|
|
UTM
|
67kip
|
|
Specimen Identification
|
Wire Rope
|
|
Peak Load
|
11895.4
|
|
Operator
|
5/16 Red 1
|
|
Location of Failure
|
At Crimp
|
DIME Test ID: 2024-01-29-57-3
Test Method: ASTM A931-18: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 04/23/2024
Date Tested: 04/23/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Broke in Wire Right at Crimp
Test Result Compliance:
Additional Comments When Verified:
|
Temperature
|
72 F
|
|
UTM
|
67kip
|
|
Specimen Identification
|
Wire Rope
|
|
Peak Load
|
12057.4
|
|
Operator
|
5/16 Red 2
|
|
Location of Failure
|
At Crimp
|
DIME Test ID: 2024-01-29-57-4
Test Method: ASTM A931-18: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 04/23/2024
Date Tested: 04/23/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Broke in Wire
Test Result Compliance:
Additional Comments When Verified:
|
Temperature
|
72 F
|
|
UTM
|
67kip
|
|
Specimen Identification
|
Wire Rope
|
|
Peak Load
|
15870.3
|
|
Operator
|
3/8
|
|
Location of Failure
|
Below Crimp
|
DIME Test ID: 2024-01-29-57-5
Test Method: ASTM A931-18: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 04/23/2024
Date Tested: 04/23/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Broke in Wire at Crimp
Test Result Compliance:
Additional Comments When Verified:
|
Temperature
|
72 F
|
|
UTM
|
67kip
|
|
Specimen Identification
|
Wire Rope
|
|
Peak Load
|
29484.9
|
|
Operator
|
1/2
|
|
Location of Failure
|
At Crimp
|