Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 209698 DEA: 072332E4 EFIS: 0700000391 COOP: 0705187
QA Service Level: 2
DIST-CO-RTE-PM: 07-LA-I-5-45.4/54
Work Description: Addition of 14 miles of HOV lanes in both directions would extend existing carpool lanes on the I- 5 in San Fernando Valley to Santa Clarita Valley
Location Description: The I-5 North Capacity Enhancements Project focuses on improvements to the I-5 freeway from cities of Santa Clarita and Castaic, beginning at the SR-14 interchange to Parker Rd.
Contractor Name: Not yet Awarded
Contractor Address: Unknown
Resident Engineer: Emile Eid Structure Rep.: Chanh Tong
DIME Sample ID: 2023-09-18-119
TL Number from the TL Form:
Sample Submitted By Organization: Con-Fab California, LLC
Sample Organization Contact: (661) 630-7162
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 09/18/2023
Date that the sample was received by the laboratory/organization performing the testing: 09/18/2023
The quantity of what the sample constitutes: 1 Bucket of 1/2", 1 Bucket of 3/8", One Bucket of Sand
A brief description of the sample: 1 Bucket of 1/2", 1 Bucket of 3/8", One Bucket of Sand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Con-Fab California, LLC - Shafter
Source Identification (SMARA, name of Pit or Job Site): Con-Fab California, LLC
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Stockpile at the Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
DIME Test ID: 2023-09-18-119-1
Test Method: ASTM C136-19: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 06/11/2024
Date Tested: 09/18/2023
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: (661) 630-3281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested?
|
Combined Gradation
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
Cumulative percent passing the 1/2 in. sieve
|
93.5 %
|
Cumulative percent passing the 3/8 in. sieve
|
73.7 %
|
Cumulative percent passing the #4 sieve
|
53.3 %
|
Cumulative percent passing the #8 sieve
|
43.8 %
|
Cumulative percent passing the #16 sieve
|
34.8 %
|
Cumulative percent passing the #30 sieve
|
22 %
|
Cumulative percent passing the #50 sieve
|
9.7 %
|
Cumulative percent passing the #100 sieve
|
2.4 %
|
Cumulative percent passing the #200 sieve
|
0.3 %
|
DIME Test ID: 2023-09-18-119-2
Test Method: ASTM D2419-14: Standard Test Method for Sand Equivalent Value of Soils and Fine Aggregate
Verified Date: 06/11/2024
Date Tested: 09/18/2023
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: (661) 630-3281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2023-09-18-119-3
Test Method: ASTM C117-17: Standard Test Method for Materials Finer than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Verified Date: 06/11/2024
Date Tested: 09/18/2023
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: (661) 630-3281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Percent finer than No. 200 sieve
|
2.4 %
|
DIME Test ID: 2023-09-18-119-4
Test Method: ASTM C566-19: Standard Test Method for Total Evaporable Moisture Content of Aggregate by Drying
Verified Date: 06/11/2024
Date Tested: 09/18/2023
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: (661) 630-3281
General Comments for this Test: Sand 5.5%, 3/8 inch rock 1.5%, 1/2 inch rock 1.0%
Test Result Compliance:
Additional Comments When Verified:
Total evaporable moisture content
|
5.5 %
|