Print Report | Back to Sample Detail

Sample Record for 2024-04-15-19

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994997 DEA: 030H1614 EFIS: 0323000025 QA Service Level: 1
DIST-CO-RTE-PM: 03-YUB-70-14.8/15.7
Work Description:
Location Description:
Contractor Name: GRANITE CONSTRUCTION
Contractor Address: 4001 BRADSHAW ROAD, SACRAMENTO, CA 95827
Resident Engineer: Selvendran Manoharan Structure Rep.: Travis Christie

Sample Information

DIME Sample ID: 2024-04-15-19
TL Number from the TL Form:
Sample Submitted By Organization: CT SC - 3667 - Chico
Sample Organization Contact: (530) 713-7871
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/15/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/17/2024
The quantity of what the sample constitutes: Discharge Structure Walls and Tops
A brief description of the sample: PCC
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex

Material Information

The concrete mix design number: 1615453
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 31164241
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2024-04-15-19-1
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 04/22/2024
Date Tested: 04/22/2024
Submitted By Organization: CT D03 - Chico Field Laboratory
Organization Address: 2707 Notre Dame Boulevard,
Organization City: Chico
Organization State: CA
Organization Zipcode: 95928
Organization Email: bmckeehan@ghirardelliassoc.com
Organization Phone: (916) 799-4305
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 3320 psi
Maximum load on cylinder 1 41970 lb
Maximum load on cylinder 2 42810 lb
Maximum load on cylinder 3 40500 lb
Compressive strength of cylinder 1 3338.9 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 3405.7 psi
Compressive strength of cylinder 3 3222 psi
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours 0 hours