Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994903 DEA: 11430244 EFIS: 1118000033
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-125-9.3/13.0
Work Description: PLACE HMA, RHMA, SLAB REPLACEMENT, AND ELECTRICAL WORK.
Location Description: SAN DIEGO COUNTY IN AND NEAR LEMON GROVE FROM 0.3 MILE SOUTH OF ELKELTON PLACE UNDERCROSSING TO 0.2 MILE SOUTH OF ROUTE 125/94 SEPARATION
Contractor Name: HAZARD CONSTRUCTION ENGR LLC
Contractor Address: 10529 Vine Street, Lakeside, CA 92040
Resident Engineer: Sultan Ghazialam Structure Rep.: Unknown
DIME Sample ID: 2024-04-13-1
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/13/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/15/2024
The quantity of what the sample constitutes: 12 boxes
A brief description of the sample: 3/4" HMA PSU
From where was the sample collected: Source
Laboratory sample identification: 0109-PSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay
DIME Test ID: 2024-04-13-1-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/14/2024
Date Tested: 04/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies within 4.7% target value range.
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4027.5 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6063.7 g
|
|
Mass of HMA Sample prior to ignition
|
2036.2 g
|
|
Corrected Asphalt Binder Content
|
5.09 %
|
|
Mass Loss
|
117.5 g
|
|
Mass of aggregate remaining after ignition
|
1918.7 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.68 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
1000.4 F
|
DIME Test ID: 2024-04-13-1-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/14/2024
Date Tested: 04/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7477.1 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2521 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8997.6 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.52
|
|
Theoretical maximum density at 25°C (77°F)
|
2513 kg/m^3
|
DIME Test ID: 2024-04-13-1-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 05/14/2024
Date Tested: 04/19/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies within 4% +/- 1.5
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
3.7 %
|
|
Percent Air Voids 2
|
4.1 %
|
|
Percent Air Voids 3
|
3.9 %
|
|
Average Percent Air Voids
|
3.9 %
|
DIME Test ID: 2024-04-13-1-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 05/14/2024
Date Tested: 04/19/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Test results are within specification limits.
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.426
|
|
Bulk Specific Gravity 2
|
2.417
|
|
Bulk Specific Gravity 3
|
2.422
|
|
Average Bulk Specific Gravity
|
2.422
|
DIME Test ID: 2024-04-13-1-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 05/14/2024
Date Tested: 04/24/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
207 psi
|
|
Average Wet Tensile Strength
|
410 psi
|
|
Tensile Strength Ratio
|
1.98
|
DIME Test ID: 2024-04-13-1-6
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 05/14/2024
Date Tested: 04/24/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target <12.0
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
no data
|
|
Test Temperature
|
122 F
|
|
Air Void Content for specimen A-1
|
no data
|
|
Air Void Content for specimen A-2
|
no data
|
|
Air Void Content for specimen B-1
|
no data
|
|
Air Void Content for specimen B-2
|
no data
|
|
Stripping Inflection Point (Wheel A)
|
15000
|
|
Stripping Inflection Point (Wheel B)
|
15000
|
|
Maximum impression at 5000 passes (left wheel)
|
2.19 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
1.65 mm
|
|
Average impression at 5000 passes (left/right avg)
|
1.92 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
2.4 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
2.3 mm
|
|
Average impression at 10000 passes (left/right avg)
|
2.35 mm
|
|
Maximum impression at 15000 passes (left wheel)
|
3.03 mm
|
|
Maximum impression at 15000 passes (right wheel)
|
2.31 mm
|
|
Average impression at 15000 passes (left/right avg)
|
2.67 mm
|
|
Average impression at 20000 passes (left/right avg)
|
no data
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|
DIME Test ID: 2024-04-13-1-7
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/14/2024
Date Tested: 04/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 3 RAP burns
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4011.3 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5519.8 g
|
|
Mass of HMA Sample prior to ignition
|
1508.5 g
|
|
Corrected Asphalt Binder Content
|
6.99 %
|
|
Mass Loss
|
105.5 g
|
|
Mass of aggregate remaining after ignition
|
1403 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
1000.4 F
|
DIME Test ID: 2024-04-13-1-8
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/14/2024
Date Tested: 04/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: RAP Rice
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7477.1 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1546.9 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8383.6 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.416
|
|
Theoretical maximum density at 25°C (77°F)
|
2409 kg/m^3
|