Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for storing JMF sample data
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2024-03-14-59
TL Number from the TL Form:
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 03/14/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/14/2024
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: Combined Untreated Virgin Aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tullis — Northstate Asphalt (Redding, CA) — Latona Aggregates (Anderson, CA)
Source Identification (SMARA, name of Pit or Job Site): 91-45-0061::Latona Aggregates (Anderson, CA)
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Laboratory Batched from Sized Untreated Virgin Aggregate Stockpile Samples
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
DIME Test ID: 2024-03-14-59-1
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 04/15/2024
Date Tested: 03/27/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Submitted from JMF - Ward Jenkins
Test Result Compliance:
Additional Comments When Verified:
Method
|
1 - Combined Fracture Determination
|
Aggregate Size and Fracture Type
|
Coarse 1 and 2 Faced and Fine 1 Faced
|
Percentage of fractured, coarse, 2 faced particles tested
|
100 %
|
Percentage of fractured, coarse, 1 faced particles tested
|
100 %
|
Percentage of fractured, fine, 1 faced particles tested
|
100 %
|
DIME Test ID: 2024-03-14-59-2
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 04/15/2024
Date Tested: 03/27/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Submitted from JMF - Ward Jenkins
Test Result Compliance:
Additional Comments When Verified:
Grading designation
|
no data
|
Percent loss after 100 revolutions
|
3 %
|
Percent loss after 500 revolutions
|
17 %
|
DIME Test ID: 2024-03-14-59-3
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 04/15/2024
Date Tested: 03/27/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Submitted from JMF - Ward Jenkins
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2024-03-14-59-4
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 04/15/2024
Date Tested: 03/27/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Submitted from JMF - Ward Jenkins
Test Result Compliance:
Additional Comments When Verified:
What test method is performed?
|
Method A
|
Bulk dry specific gravity
|
no data
|
Average uncompacted voids
|
46.2 %
|
DIME Test ID: 2024-03-14-59-5
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 04/15/2024
Date Tested: 03/27/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Submitted from JMF - Ward Jenkins
Test Result Compliance:
Additional Comments When Verified:
Method
|
B
|
Determination
|
By Mass
|
Dimensional ratio used
|
5:1
|
Weighted percentage of particles (by mass) that were flat and elongated
|
1 %
|
Weighted percentage of particles (by mass) that were not flat and elongated
|
no data
|
DIME Test ID: 2024-03-14-59-6
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Verified Date: 04/15/2024
Date Tested: 03/28/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Submitted from JMF - Ward Jenkins
Test Result Compliance:
Additional Comments When Verified:
Oops.. looks like no test results have been submitted for the test.
DIME Test ID: 2024-03-14-59-7
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 04/15/2024
Date Tested: 03/28/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Submitted from JMF - Ward Jenkins
Test Result Compliance:
Additional Comments When Verified:
Basis for relative density testing
|
Bulk
|
Specific Gravity
|
2.674
|
Absorption
|
1.4 %
|
DIME Test ID: 2024-03-14-59-8
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 04/15/2024
Date Tested: 04/05/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Submitted from JMF - Ward Jenkins
Test Result Compliance:
Additional Comments When Verified:
Bulk specific gravity
|
2.515
|
Bulk specific gravity (SSD Basis)
|
2.606
|
Apparent specific gravity
|
2.766
|
Absorption
|
3.6 %
|
DIME Test ID: 2024-03-14-59-9
Test Method: AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)
Verified Date: 04/15/2024
Date Tested: 03/27/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Submitted from JMF - Ward Jenkins
Test Result Compliance:
Additional Comments When Verified:
Which test procedure(s) is/are used?
|
Procedure A and Procedure B
|
Was strict temperature control maintained?
|
no data
|
What type of water was used?
|
no data
|
Durability Index (coarse)
|
87
|
Durability Index (fine)
|
82
|