Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995263 DEA: 061G3304 EFIS: 0624000029
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-180-118/138
Work Description: FRE 180 Emergency Slope Repairs.
Location Description:
Contractor Name: CAL VALLEY CONSTRUCTION
Contractor Address: 5125 N. Gates Ave, Ste 102, Fresno, CA 93722
Resident Engineer: Mark Mengoni Structure Rep.: Benjamin Holton
DIME Sample ID: 2024-04-10-21
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 341-3953
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 04/10/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/12/2024
The quantity of what the sample constitutes: 57 CY
A brief description of the sample: PCC cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 06-1G3304, at PM 126.5
Structure name: Retaining Wall, Barrier Slab
The fabricator/manufacturer/facility name: Outback Materials, Fresno
The concrete mix design number: 72T1X39
The truck number from where the sample was collected: 113
The batch plant ticket number from where the sample was collected: 157446
Concrete batch plant: Outback Materials
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled: Barrier Slab.
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-04-10-21-1
Test Method: ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 05/04/2024
Date Tested: 04/10/2024
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2024-04-10-21-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/04/2024
Date Tested: 05/04/2024
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
4660 psi
|
|
Maximum load on cylinder 1
|
56400 lb
|
|
Maximum load on cylinder 2
|
57630 lb
|
|
Maximum load on cylinder 3
|
61880 lb
|
|
Compressive strength of cylinder 1
|
4486.9 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
4584.7 psi
|
|
Compressive strength of cylinder 3
|
4922.8 psi
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
24 days
|
|
Age of specimen in hours
|
no data0 hours
|
DIME Test ID: 2024-04-10-21-3
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/08/2024
Date Tested: 05/08/2024
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
3.99 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
3.99 in
|
|
Cross sectional area of cylinder 1
|
12.5 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.5 in^2
|
|
Compressive strength (to nearest 10 psi)
|
5360 psi
|
|
Maximum load on cylinder 1
|
66980 lb
|
|
Maximum load on cylinder 2
|
67190 lb
|
|
Maximum load on cylinder 3
|
67140 lb
|
|
Compressive strength of cylinder 1
|
5358.4 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
5345.3 psi
|
|
Compressive strength of cylinder 3
|
5371.2 psi
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|