Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for storing JMF sample data
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2024-03-14-51
TL Number from the TL Form:
Sample Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Sample Organization Contact: (530) 741-4238
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 03/14/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/15/2024
The quantity of what the sample constitutes: Bags of Aggs
A brief description of the sample: 3/4" Virgin Aggregate
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: KRC Hallwood
Source Identification (SMARA, name of Pit or Job Site): 91-58-0002
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
DIME Test ID: 2024-03-14-51-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 03/29/2024
Date Tested: 03/18/2024
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: Submitted from JMF - Julian Gonzales
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested?
|
HMA Gradation
|
Cumulative percent passing the 1 1/2 in. sieve
|
no data
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
95 %
|
Cumulative percent passing the 1/2 in. sieve
|
80 %
|
Cumulative percent passing the 3/8 in. sieve
|
66 %
|
Cumulative percent passing the #4 sieve
|
44 %
|
Cumulative percent passing the #8 sieve
|
35 %
|
Cumulative percent passing the #16 sieve
|
25 %
|
Cumulative percent passing the #30 sieve
|
17 %
|
Cumulative percent passing the #50 sieve
|
11 %
|
Cumulative percent passing the #100 sieve
|
6 %
|
Cumulative percent passing the #200 sieve
|
4.1 %
|