Print Report | Back to Sample Detail

Sample Record for 2024-03-07-30

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214487 DEA: 120Q9304 EFIS: 1217000128 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5,133,241-122,241-var
Work Description: 12-0Q930, SHOPP RESERVATION BRIDGE PROJECT - BRIDGE UPGRADE, WINGWALL, SUBSTRUCTURE, DECK, SPALL, JOINT SEAL, CONC.
Location Description: ORANGE COUNTY AT VARIOUS LOCATIONS
Contractor Name: PETERSON CHASE GENERAL ENGINEERING CONSTRUCTION INC
Contractor Address: 1792 KAISER AVENUE, IRVINE CA 92614
Resident Engineer: Mario Leon Structure Rep.: Josefino Valencia

Sample Information

DIME Sample ID: 2024-03-07-30
TL Number from the TL Form:
Sample Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Sample Organization Contact: 9492798846
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 03/07/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/08/2024
The quantity of what the sample constitutes: 2
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 24-0086
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Peterson Chase

Material Information

The concrete mix design number: 556300
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled: Irvine OH Bridge Location 13 Sta 484 82 to 485 88
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2024-03-07-30-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 04/04/2024
Date Tested: 04/04/2024
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 5.98 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.08 in^2
Cross sectional area of cylinder 2 28.17 in^2
Compressive strength (to nearest 10 psi) 4190 psi
Maximum load on cylinder 1 116050 lb
Maximum load on cylinder 2 119700 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours no data0 hours