Project ID: 994595 DEA: 081M2204 EFIS: 0821000094
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15,138,173-Var
Work Description: POLYESTER CONCRETE OVERLAY AND REPLACE JOINT SEALS.
Location Description: SAN BERNARDINO COUNTY AT VARIOUS LOCATIONS.
Contractor Name: MYERS & SONS CONSTRUCTION, LLC
Contractor Address: Unknown
Resident Engineer: Xavier Avila Structure Rep.: Ravinder S Singh
DIME Sample ID: 2024-03-25-21
TL Number from the TL Form: 1064-325
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 03/25/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/27/2024
The quantity of what the sample constitutes: 4
A brief description of the sample: Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 1064-325
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: George Throop
The concrete mix design number: 2007-007
The truck number from where the sample was collected: 114
The batch plant ticket number from where the sample was collected: 8466
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: SB 138 Bridge
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-03-25-21-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C1231 - Unbonded Elastomeric Pad Cap Cured in accordance with ASTM C511
Verified Date: 05/06/2024
Date Tested: 03/28/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
12.69 in^2
|
|
Cross sectional area of cylinder 2
|
12.69 in^2
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Compressive strength (to nearest 10 psi)
|
6390 psi
|
|
Average diameter of cylinder 1
|
4.02 in
|
|
Average diameter of cylinder 2
|
4.02 in
|
|
Compressive strength of cylinder 1
|
6606.8 psi
|
|
Compressive strength of cylinder 2
|
6178.9 psi
|
|
Maximum load on cylinder 1
|
83840 lb
|
|
Maximum load on cylinder 2
|
78410 lb
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
3 days
|
DIME Test ID: 2024-03-25-21-2
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C1231 - Unbonded Elastomeric Pad Cap Cured in accordance with ASTM C511
Verified Date: 05/06/2024
Date Tested: 04/03/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
12.63 in^2
|
|
Cross sectional area of cylinder 2
|
12.69 in^2
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Compressive strength (to nearest 10 psi)
|
6880 psi
|
|
Average diameter of cylinder 1
|
4.01 in
|
|
Average diameter of cylinder 2
|
4.02 in
|
|
Compressive strength of cylinder 1
|
6992.1 psi
|
|
Compressive strength of cylinder 2
|
6774.6 psi
|
|
Maximum load on cylinder 1
|
88310 lb
|
|
Maximum load on cylinder 2
|
85970 lb
|
|
Type of fracture pattern of cylinder 1
|
1
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
9 days
|