Print Report | Back to Sample Detail

Sample Record for 2024-03-09-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994582 DEA: 073203U4 EFIS: 0722000071 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-91,605-R16.6/R16.8,R0.0/R10.4
Work Description: PLACE CONCRETE PAVEMENT AND HIGH FRICTION SURFACE TREATMENT.
Location Description: LOS ANGELES COUNTY ON ROUTE 605 FROM 0.2 MILE NORTH OF KATELLA AVENUE UNDECROSSING TO 0.1 MILE NORTH OF TELEGRAPH ROAD UNDERCROSSING AND ON ROUTE 91 FROM 0.4 MILE WEST OF ROUTE 605 UNDERCROSSING TO 0.2 MILE WEST OF ROUTE 605 UNDERCROSSING
Contractor Name: RASMUSSEN/VANGUARD
Contractor Address: 28548 LIVINGSTON AVENUE, VALENCIA CA 91335
Resident Engineer: George Malacalza Structure Rep.: Tien Chu

Sample Information

DIME Sample ID: 2024-03-09-9
TL Number from the TL Form:
Sample Submitted By Organization: Alta Vista Solutions - Whittier
Sample Organization Contact: (510) 542-9827
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 03/09/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/09/2024
The quantity of what the sample constitutes: 10 cubic yards
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Source
Laboratory sample identification: 24-0418
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: N/A

Material Information

The concrete mix design number: CTS-72-EHI / 1200psi @ 2hrs
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Load 2
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2024-03-09-9-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/27/2024
Date Tested: 03/19/2024
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 5.99 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.18 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 5680 psi
Maximum load on cylinder 1 161065 lb
Maximum load on cylinder 2 159475 lb
Compressive strength of cylinder 1 5715.6 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 5641.1 psi
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 10 days
Age of specimen in hours 0 hours

Test 2 of 2

DIME Test ID: 2024-03-09-9-2
Test Method: CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete
Verified Date: 03/27/2024
Date Tested: 03/09/2024
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 74 F