Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214698 DEA: 120N8904 EFIS: 1214000130
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-133-8.3/M9.3
Work Description: CONSTRUCT AUXILIARY LANE.
Location Description: ORANGE COUNTY IN IRVINE FROM ROUTE 133/405 SEPARATION TO IRVINE CENTER DRIVE OVERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3200 Park Center Drive, Suite #200, Costa Mesa, CA 92626
Resident Engineer: Arezo Ghiam Structure Rep.: Michael Yee
DIME Sample ID: 2024-03-12-37
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/12/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/21/2024
The quantity of what the sample constitutes: 19 BOXES OF HMA, 2 BAGS AGGS, 2 BAGS RAP, 3 QTS PG58-16
A brief description of the sample: 3/4" HMA-A-SP R25
From where was the sample collected: Manufacturer
Laboratory sample identification: 0147A-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: VULCAN CORONA DRUM
DIME Test ID: 2024-03-12-37-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/17/2024
Date Tested: 03/23/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7352.3 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2554.3 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8885.3 grams
|
|
Temperature of Water
|
25 °F
|
|
Specific Gravity for Sample 1
|
2.501
|
|
Theoretical maximum density at 25°C (77°F)
|
2494 kg/m^3
|
DIME Test ID: 2024-03-12-37-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 05/17/2024
Date Tested: 03/25/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
4.2 %
|
|
Percent Air Voids 2
|
4.2 %
|
|
Percent Air Voids 3
|
4.2 %
|
|
Average Percent Air Voids
|
4.2 %
|
DIME Test ID: 2024-03-12-37-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 05/17/2024
Date Tested: 03/25/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.397
|
|
Bulk Specific Gravity 2
|
2.396
|
|
Bulk Specific Gravity 3
|
2.396
|
|
Average Bulk Specific Gravity
|
2.396
|
DIME Test ID: 2024-03-12-37-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/17/2024
Date Tested: 03/23/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
2168 g
|
|
Corrected Asphalt Binder Content
|
4.74 %
|
|
Mass Loss
|
112 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.29 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.14 %
|
|
Test Temperature
|
538 C
|