Project ID: 213457 DEA: 11430434 EFIS: 1118000197
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-8-12.9/14.6,14.9
Work Description: HMA, STRUCTURAL BRIDGE, POLYESTER CONC OVERLAY, JPCP, & CONC BARRIER.
Location Description: SAN DIEGO COUNTY IN LA MESA AND EL CAJON FROM 0.1 MILE WEST OF GROSSMONT BOULEVARD OVERCROSSING TO WEST MAIN STREET OVERCROSSING AND AT MARSHALL AVENUE OVERHEAD
Contractor Name: Griffith Company
Contractor Address: 13400 Sabre Springs Parkway, Suite 200, SAN DIEGO, CA 92128
Resident Engineer: Chad Lim Structure Rep.: Janelle Clanton
DIME Sample ID: 2024-03-16-11
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/16/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/19/2024
The quantity of what the sample constitutes: 2 boxes
A brief description of the sample: 3/4" HMA
From where was the sample collected: Source
Laboratory sample identification: 7816-A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay
DIME Test ID: 2024-03-16-11-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 03/27/2024
Date Tested: 03/21/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.70% -.3 to +.5 Tested 4.87 %
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4014.7 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6083.2 g
|
|
Mass of HMA Sample prior to ignition
|
2068.5 g
|
|
Corrected Asphalt Binder Content
|
4.87 %
|
|
Mass Loss
|
114.9 g
|
|
Mass of aggregate remaining after ignition
|
1953.6 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.68 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2024-03-16-11-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 03/27/2024
Date Tested: 03/21/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 2.515 +/- .02 Tested 2.512
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7477.1 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2558.6 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
9017.3 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.512
|
|
Theoretical maximum density at 25°C (77°F)
|
156.4 lb/ft^3
|