Print Report | Back to Sample Detail

Sample Record for 2024-03-11-21

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994116 DEA: 010J4104 EFIS: 0119000025 QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-299-30.7/33.4
Work Description: Project Name: HUM-299 Curve Improvement
Location Description: HUMBOLDT COUNTY NEAR WILLOW CREEK FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 0.1 MILE EAST OF EAST FORK WILLOW CREEK BRIDGE
Contractor Name: McCullough Construction Inc.
Contractor Address: 57 Alder Grove Road, Arcata, CA 95521
Resident Engineer: Ethan Retherford Structure Rep.: Laura Cangas

Sample Information

DIME Sample ID: 2024-03-11-21
TL Number from the TL Form:
Sample Submitted By Organization: Universal Precast Concrete - Redding
Sample Organization Contact: (530) 243-6477
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 03/11/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/11/2024
The quantity of what the sample constitutes: 542.7g
A brief description of the sample: Fine Agg - Sand
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Folsom Ready Mix

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-45-0061
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Stockpile
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: fine
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 4

DIME Test ID: 2024-03-11-21-1
Test Method: ASTM C117-17: Standard Test Method for Materials Finer than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Verified Date: 03/27/2024
Date Tested: 03/12/2024
Submitted By Organization: Universal Precast Concrete - Redding
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Percent finer than No. 200 sieve 3.7 %

Test 2 of 4

DIME Test ID: 2024-03-11-21-2
Test Method: ASTM C136-19: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 03/27/2024
Date Tested: 03/12/2024
Submitted By Organization: Universal Precast Concrete - Redding
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? Fine Aggregate
Cumulative percent passing the 3/8 in. sieve 100 %
Cumulative percent passing the #4 sieve 97 %
Cumulative percent passing the #8 sieve 68 %
Cumulative percent passing the #16 sieve 45 %
Cumulative percent passing the #30 sieve 27 %
Cumulative percent passing the #50 sieve 12 %
Cumulative percent passing the #100 sieve 6 %
Cumulative percent passing the #200 sieve 3.9 %

Test 3 of 4

DIME Test ID: 2024-03-11-21-3
Test Method: ASTM C566-19: Standard Test Method for Total Evaporable Moisture Content of Aggregate by Drying
Verified Date: 03/27/2024
Date Tested: 03/11/2024
Submitted By Organization: Universal Precast Concrete - Redding
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total evaporable moisture content 8.3 %

Test 4 of 4

DIME Test ID: 2024-03-11-21-4
Test Method: ASTM D2419-14: Standard Test Method for Sand Equivalent Value of Soils and Fine Aggregate
Verified Date: 03/27/2024
Date Tested: 03/12/2024
Submitted By Organization: Universal Precast Concrete - Redding
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sand Equivalent 78