Project ID: 211080 DEA: 060V0304
QA Service Level: 1
DIST-CO-RTE-PM: 06-KER-99-7.3
Work Description: Girder replacement and repairs due to bridge hit
Location Description: Near Bakersfield, from 7.3 miles N of the Rte 99/5 Jct to 6.1 miles S of the Rte 99/119 Jct at Ker 99-7.29
Contractor Name: GRIFFITH COMPANY
Contractor Address: 1128 Carrier Parkway Ave, Bakersfield, CA 93308
Resident Engineer: Hisham Alnatour Structure Rep.: Mike Trinh
DIME Sample ID: 2024-03-14-30
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 341-3953
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 03/14/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/15/2024
The quantity of what the sample constitutes: 4 sets cylinders
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Viking
The concrete mix design number: NCT09064
The truck number from where the sample was collected: 117187984
The batch plant ticket number from where the sample was collected: Abut 8 piles
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: From the truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-03-14-30-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/21/2024
Date Tested: 03/21/2024
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
3950 psi
|
|
Maximum load on cylinder 1
|
50820 lb
|
|
Maximum load on cylinder 2
|
48630 lb
|
|
Maximum load on cylinder 3
|
49320 lb
|
|
Compressive strength of cylinder 1
|
4043.0 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
3868.7 psi
|
|
Compressive strength of cylinder 3
|
3923.6 psi
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
7 days
|
|
Age of specimen in hours
|
no data0 hours
|