Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 213457 DEA: 11430434 EFIS: 1118000197
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-8-12.9/14.6,14.9
Work Description: HMA, STRUCTURAL BRIDGE, POLYESTER CONC OVERLAY, JPCP, & CONC BARRIER.
Location Description: SAN DIEGO COUNTY IN LA MESA AND EL CAJON FROM 0.1 MILE WEST OF GROSSMONT BOULEVARD OVERCROSSING TO WEST MAIN STREET OVERCROSSING AND AT MARSHALL AVENUE OVERHEAD
Contractor Name: Griffith Company
Contractor Address: 13400 Sabre Springs Parkway, Suite 200, SAN DIEGO, CA 92128
Resident Engineer: Chad Lim Structure Rep.: Janelle Clanton
DIME Sample ID: 2024-03-14-26
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/14/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/15/2024
The quantity of what the sample constitutes: 12 boxes
A brief description of the sample: 3/4" HMA PSU
From where was the sample collected: Source
Laboratory sample identification: 7815-PSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay
DIME Test ID: 2024-03-14-26-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 03/26/2024
Date Tested: 03/19/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.70% -.3 to +.5 Tested 4.72
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4026.1 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6076.6 g
|
|
Mass of HMA Sample prior to ignition
|
2050.5 g
|
|
Corrected Asphalt Binder Content
|
4.72 %
|
|
Mass Loss
|
110.7 g
|
|
Mass of aggregate remaining after ignition
|
1939.8 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.68 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2024-03-14-26-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 03/26/2024
Date Tested: 03/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 2.515 Tested 2.521
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Specific Gravity for Sample 1
|
2.521
|
|
Theoretical maximum density at 25°C (77°F)
|
2.5 lb/ft^3
|
DIME Test ID: 2024-03-14-26-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 03/26/2024
Date Tested: 03/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0% +/- 1.5% Tested 4.0%
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.421
|
|
Bulk Specific Gravity 2
|
2.421
|
|
Bulk Specific Gravity 3
|
2.419
|
|
Average Bulk Specific Gravity
|
2.42
|
DIME Test ID: 2024-03-14-26-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 03/26/2024
Date Tested: 03/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0 % +/- 1.5% Tested 4.0%
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
4 %
|
|
Percent Air Voids 2
|
4 %
|
|
Percent Air Voids 3
|
4 %
|
|
Average Percent Air Voids
|
4 %
|
DIME Test ID: 2024-03-14-26-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 03/26/2024
Date Tested: 03/26/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target DRY >100 WET > 70
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
200 psi
|
|
Average Wet Tensile Strength
|
174 psi
|
|
Tensile Strength Ratio
|
0.87
|
DIME Test ID: 2024-03-14-26-6
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 03/26/2024
Date Tested: 03/22/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies <12.7 mm
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
no data
|
|
Test Temperature
|
122 F
|
|
Air Void Content for specimen A-1
|
no data
|
|
Air Void Content for specimen A-2
|
no data
|
|
Air Void Content for specimen B-1
|
no data
|
|
Air Void Content for specimen B-2
|
no data
|
|
Stripping Inflection Point (Wheel A)
|
15000
|
|
Stripping Inflection Point (Wheel B)
|
15000
|
|
Maximum impression at 5000 passes (left wheel)
|
1.06 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
1.29 mm
|
|
Average impression at 5000 passes (left/right avg)
|
1.18 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
2.1 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
2.46 mm
|
|
Average impression at 10000 passes (left/right avg)
|
2.28 mm
|
|
Maximum impression at 15000 passes (left wheel)
|
3.08 mm
|
|
Maximum impression at 15000 passes (right wheel)
|
3.67 mm
|
|
Average impression at 15000 passes (left/right avg)
|
3.38 mm
|
|
Average impression at 20000 passes (left/right avg)
|
no data
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|
DIME Test ID: 2024-03-14-26-7
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 03/26/2024
Date Tested: 03/19/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 3 RAP Burns COMPLY R1=9.10% R2=7.94% R3=8.66%
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4028.6 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5694.7 g
|
|
Mass of HMA Sample prior to ignition
|
1666.1 g
|
|
Corrected Asphalt Binder Content
|
8.66 %
|
|
Mass Loss
|
144.3 g
|
|
Mass of aggregate remaining after ignition
|
1521.8 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|