Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 042G8504 Cty ALA Rte 580 PM R4.0 Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Satinder Grewal |
Date Reported: |
08/22/2016 |
|
|
Address: |
TL Number: |
180015 |
||
|
City: |
||||
|
Project Name: CONSTRUCT A 600 FOOT SOLDIER PILE AND LAGGING WALL WITH GROUND ANCHOR |
||||
|
Prime Contractor: RGW |
||||
|
Sample Taken Date: |
08/06/2016 |
Mix Design: |
1416245 |
|
|
Contractor: Unknown |
Location : CONSTRUCT A 600 FOOT SOLDIER PILE AND LAGGING WALL WITH GROUND ANCHOR |
|||
|
Structure unique identifier: Unknown |
||||
|
Structure name: Unknown |
||||
|
Location of Pour: Unknown |
||||
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 27.99 | 5.97 | 4279.0 | 119768 | 1 |
| 2 | 28.09 | 5.98 | 4388.6 | 123276 | 1 |
DIME Test ID: 2016-08-06-1-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4330
Age of specimen: 16 days
Certified By: Mike Mullins
|
*Subject to final inspection by the Resident Engineer. |
|
TL- Report of Laboratory Testing