Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-0.0/13.2
Work Description: Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location Description: LA/SBD County Line to PM 13.2 near I-15
Contractor Name: Lane-Security Paving Joint Venture
Contractor Address: 3450 Centre Lake Drive, 1st Floor, Ontario, CA 91761
Resident Engineer: Jose Corona Structure Rep.: Luis Negrete
DIME Sample ID: 2024-03-07-23
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 03/07/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/08/2024
The quantity of what the sample constitutes: 18 totes
A brief description of the sample: 1 gallon can / PPC 1121 RESIN
From where was the sample collected: Source
Laboratory sample identification: 000043KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia
DIME Test ID: 2024-03-07-23-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 05/13/2024
Date Tested: 04/09/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2024-03-07-23-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 05/13/2024
Date Tested: 04/09/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units
|
pounds/gallons
|
Liquid Density (pounds per gallon)
|
9
|
DIME Test ID: 2024-03-07-23-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 05/13/2024
Date Tested: 03/14/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Vendors Results
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested
|
6
|
Conditioning procedure
|
18/25/50+5/70
|
Speed of testing
|
0.45 in/min
|
Sample 1 Width
|
0.484 in
|
Sample 1 Ultimate strength
|
3291.9 psi
|
Sample 1 Thickness
|
0.256 in
|
Sample 1 Area
|
0.1239 in^2
|
Sample 1 Ultimate Strength Actual
|
407.87 lbs
|
Sample 1 percent elongation
|
57.4 %
|
Sample 1 Time
|
0 MM:SS
|
Sample 2 Width
|
0.484 in
|
Sample 2 Thickness
|
0.259 in
|
Sample 2 Area
|
0.1254 in^2
|
Sample 2 Ultimate strength
|
3252 psi
|
Sample 2 Ultimate Strength Actual
|
407.8 lbs
|
Sample 2 percent elongation
|
65 %
|
Sample 2 Time
|
0 MM:SS
|
Sample 3 Width
|
0.484 in
|
Sample 3 Thickness
|
0.267 in
|
Sample 3 Area
|
0.1292 in^2
|
Sample 3 Ultimate strength
|
3239 psi
|
Sample 3 Ultimate Strength Actual
|
418.48 lbs
|
Sample 3 percent elongation
|
55.7 %
|
Sample 3 Time
|
0 MM:SS
|
Sample 4 Width
|
0.484 in
|
Sample 4 Thickness
|
0.266 in
|
Sample 4 Area
|
0.1287 in^2
|
Sample 4 Ultimate strength
|
3467.8 psi
|
Sample 4 Ultimate Strength Actual
|
446.3 lbs
|
Sample 4 percent elongation
|
73.8 %
|
Sample 4 Time
|
0 MM:SS
|
Sample 5 Width
|
0.484 in
|
Sample 5 Thickness
|
0.256 in
|
Sample 5 Area
|
0.1239 in^2
|
Sample 5 Ultimate strength
|
3329 psi
|
Sample 5 Ultimate Strength Actual
|
412.46 lbs
|
Sample 5 percent elongation
|
69.2 %
|
Sample 5 Time
|
0 MM:SS
|
Sample 6 Width
|
0.484 in
|
Sample 6 Thickness
|
0.265 in
|
Sample 6 Area
|
0.1283 in^2
|
Sample 6 Ultimate strength
|
3270 psi
|
Sample 6 Ultimate Strength Actual
|
419.54 lbs
|
Sample 6 percent elongation
|
41 %
|
Sample 6 Time
|
0 MM:SS
|
Ultimate Strength Average
|
3308 psi
|
Percent Elongation Average
|
60 %
|
DIME Test ID: 2024-03-07-23-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 05/13/2024
Date Tested: 04/09/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination
|
47
|
DIME Test ID: 2024-03-07-23-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 05/13/2024
Date Tested: 03/12/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Vendors Results
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1
|
24hr
|
Maximum applied load (P) for Sample 1
|
1328.73 lb
|
Span length for Sample 1
|
9 in
|
Break location for Sample 1
|
bond
|
Specimen defects/notes for Sample 1
|
no data
|
Surface type for Sample 1
|
SSD
|
Modulus of rupture (R) for Sample 1
|
664.365 psi
|
Curing history for Sample 2
|
24hr
|
Maximum applied load (P) for Sample 2
|
1363.69 lb
|
Span length for Sample 2
|
9 in
|
Break location for Sample 2
|
bond
|
Specimen defects/notes for Sample 2
|
no data
|
Surface type for Sample 2
|
SSD
|
Modulus of rupture (R) for Sample 2
|
681.843 psi
|
Curing history for Sample 3
|
24hr
|
Maximum applied load (P) for Sample 3
|
1506.58 lb
|
Span length for Sample 3
|
9 in
|
Break location for Sample 3
|
bond
|
Specimen defects/notes for Sample 3
|
no data
|
Surface type for Sample 3
|
SSD
|
Modulus of rupture (R) for Sample 3
|
753.291 psi
|
DIME Test ID: 2024-03-07-23-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 05/13/2024
Date Tested: 03/11/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid
|
153.9 mm
|
Room Temperature
|
78 f
|
Tare weight
|
no data
|
Initial weight
|
100.048 grams
|
Weight at 5 minutes
|
99.963 grams
|
Weight at 10 minutes
|
99.896 grams
|
Weight at 15 minutes
|
99.826 grams
|
Weight at 20 minutes
|
99.723 grams
|
Weight at 25 minutes
|
99.631 grams
|
Weight at 30 minutes
|
99.55 grams
|
Final weight
|
99.55 grams
|
Total weight loss
|
0.5 grams
|
Calculated radius of gallon can lid in cm
|
7.695 cm
|
Lid Factor
|
53.757 m^2
|
Volatile emission
|
26.771 grams/m^2
|