Print Report | Back to Sample Detail

Sample Record for 2024-02-23-35

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995261 DEA: 072XJ804 EFIS: 0724000004 QA Service Level: 1
DIST-CO-RTE-PM: 07---
Work Description:
Location Description:
Contractor Name: POWELL CONSTRUCTORS INC
Contractor Address: 8555 BANANA AVE, FONTANA, CA 92335
Resident Engineer: Hai Hong Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-02-23-35
TL Number from the TL Form: 021324
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 02/23/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/08/2024
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/8" HMA-A DIKE 109426
From where was the sample collected: Manufacturer
Laboratory sample identification: 24-031
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA Corona

Material Information

HMA Type: Type A HMA
HMA Grading: 3/8 inch
Lot number:
Sublot number:
HMA Mix Number: 109426
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2024-02-23-35-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 03/11/2024
Date Tested: 03/11/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4024.3 g
Mass of the specimen and specimen basket assembly prior to ignition 5547 g
Mass of HMA Sample prior to ignition 1522.7 g
Corrected Asphalt Binder Content 6.4 %
Mass Loss 97.5 g
Mass of aggregate remaining after ignition 1425.2 g
Correction Factor (Percent by mass of HMA Specimen) no data0 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C