Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 040Q30U4 Cty ALA Rte 680 PM R11.0/R21.9,R0.0/R0.9 Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Yannaing Tun |
Date Reported: |
03/01/2024 |
|
|
Address: |
TL Number: |
078101 |
||
|
City: |
||||
|
Project Name: PRECAST CONC PVMT, ELECTRONIC TOLL SYSTEM, JPCP, CB & STRUCTURAL CONC |
||||
|
Prime Contractor: BAY CITIES PAVING & GRADING (Jason Ochoa) |
||||
|
Sample Taken Date: |
02/02/2024 |
Mix Design: |
ddlsp8q3 |
|
|
Contractor: Unknown |
Location : ALAMEDA AND CONTRA COSTA COUNTIES AT SUNOL AND IN SAN RAMON BETWEEN 0.4 MILE SOUTH OF CALAVERAS ROAD UNDERCROSSING TO 0.9 MILE NORTH OF ALCOSTA BOULEVARD OVERCROSSING |
|||
|
Structure unique identifier: 01-33E0251 |
||||
|
Structure name: CIDH OS29-1 |
||||
|
Location of Pour: |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.02 | 12.69 | 65733 | 5179.0 | 1 |
| 2 | 4.03 | 12.76 | 72090 | 5652.0 | 1 |
| 3 | 4.03 | 12.76 | 57912 | 4540 | 1 |
DIME Test ID: 2024-02-02-13-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5120
Age of specimen: 28 days
Certified By: Spencer Adams
|
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing