Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for storing JMF sample data
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2023-04-17-93
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Sample Organization Contact: (510) 224-6127
Type of Sample: Quality Control
Type of Material: Asphalt Modifier
Sample Taken Date: 04/17/2023
Date that the sample was received by the laboratory/organization performing the testing: 04/17/2023
The quantity of what the sample constitutes: 100%
A brief description of the sample: 1/2" RHMA-G
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: San Joaquin
DIME Test ID: 2023-04-17-93-1
Test Method: ASTM D445-14: Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity) (Kinematic Viscosity)
Verified Date: 02/20/2024
Date Tested: 04/17/2023
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Submitted from JMF - Vuong Dao
Test Result Compliance:
Additional Comments When Verified:
|
First Kinematic Viscosity
|
no data
|
|
Second Kinematic Viscosity
|
no data
|
|
Kinematic Viscosity
|
22 m2/s
|
|
Dynamic Viscosity
|
no data
|
DIME Test ID: 2023-04-17-93-2
Test Method: ASTM D92-12b: Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester (Flash Point)
Verified Date: 02/20/2024
Date Tested: 04/17/2023
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Submitted from JMF - Vuong Dao
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Ambient Barometric Pressure unit?
|
mm Hg
|
|
Corrected Flash Point
|
425 C
|
DIME Test ID: 2023-04-17-93-3
Test Method: ASTM D2007-11: Standard Test Method for Characteristic Groups in Rubber Extender and Processing Oils and Other Petroleum-Derived Oils by the Clay-Gel Absorption Chromatographic Method (Clay Gel Absorption)
Verified Date: 02/20/2024
Date Tested: 04/17/2023
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Submitted from JMF - Vuong Dao
Test Result Compliance:
Additional Comments When Verified:
|
Method of determination of aromatic content:
|
Difference
|
|
Asphaltenes, percent by mass
|
0.0 %
|
|
Aromatics, percent by mass
|
65.0 %
|