Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for storing JMF sample data
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2023-04-17-87
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Sample Organization Contact: (510) 224-6127
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 04/17/2023
Date that the sample was received by the laboratory/organization performing the testing: 04/17/2023
The quantity of what the sample constitutes: 10%
A brief description of the sample: 1/2" RHMA-G
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DeSilva Gates Aggregates
Source Identification (SMARA, name of Pit or Job Site): 91-01-0007
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: DeSilva Gates Aggregates 91-01-0007
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: fine
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
DIME Test ID: 2023-04-17-87-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 02/20/2024
Date Tested: 04/17/2023
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Submitted from JMF - Vuong Dao
Test Result Compliance:
Additional Comments When Verified:
|
What type of gradation is being tested?
|
HMA Gradation
|
|
Cumulative percent passing the 2 in. sieve
|
no data
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
100 %
|
|
Cumulative percent passing the #4 sieve
|
100 %
|
|
Cumulative percent passing the #8 sieve
|
76 %
|
|
Cumulative percent passing the #16 sieve
|
45 %
|
|
Cumulative percent passing the #30 sieve
|
23 %
|
|
Cumulative percent passing the #50 sieve
|
9 %
|
|
Cumulative percent passing the #100 sieve
|
5 %
|
|
Cumulative percent passing the #200 sieve
|
3.2 %
|