Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 043G4744 Cty MRN Rte 580 PM 6.9/7.8,0.0/2.5 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Behzad Halali |
Date Reported: |
02/14/2024 |
|
Address: |
TL Number: |
844527 |
||
City: |
||||
Project Name: CLEAN AND PAINT STRUCTURAL STEEL BRIDGE. |
||||
Prime Contractor: Allied Painting, INC. |
||||
Sample Taken Date: |
02/07/2024 |
Mix Design: |
21005-12 |
|
Contractor: Unknown |
Location: CONTRA COSTA AND MARIN COUNTIES IN RICHMOND AND SAN RAFAEL FROM 0.8 MILE WEST OF TOLL PLAZA TO 0.1 MILE EAST OF MAIN STREET |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.03 | 12.76 | 63065 | 4944.0 | 1 |
2 | 4.02 | 12.69 | 69465 | 5473.0 | 2 |
3 | 4.03 | 12.76 | 68400 | 5362 | 1 |
DIME Test ID: 2024-02-07-8-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5260
Age of specimen: 7 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing