Print Report | Back to Sample Detail

Sample Record for 2024-01-31-30

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000105 DEA: 072XK804 QA Service Level: 1
DIST-CO-RTE-PM: 07---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-01-31-30
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Soil
Sample Taken Date: 01/31/2024
Date that the sample was received by the laboratory/organization performing the testing: 01/31/2024
The quantity of what the sample constitutes: 39 sq. yd.
A brief description of the sample: Embankment
From where was the sample collected: Job Site
Laboratory sample identification: 24-0290
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Miller

Material Information

The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: From various locations at Embankment
Where the material sample would have been placed if not sampled:

Test Results

Test 1 of 2

DIME Test ID: 2024-01-31-30-1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Verified Date: 02/06/2024
Date Tested: 01/31/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sum of Count or Density 5.88 g/cc
Average of Count or Density 1.96 g/cc
Sum of Moisture Count 0.35 g/cc
Average of Moisture Count 0.12 g/cc
Calculated Percent Relative Compaction 90.3 %
Reported Percent Relative Compaction 90 %

Test 2 of 2

DIME Test ID: 2024-01-31-30-2
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Verified Date: 02/06/2024
Date Tested: 01/31/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is oversize material No
In-place wet density 1.96
Highest adjust wet density 2.17
Relative compaction 90
% Moisture 6.5 %
Optimum Moisture 8.0 %