Contract # 030L0804 Cty SAC Rte 51 PM 5.5/5.5

Vendor #


REPORT OF LABORATORY TESTING

Resident Engineer:

Jony Tji

Date Reported:

02/15/2024

Address:

TL Number:

293954

City:

Project Name: Bridge Rail Replacement due to Vehicle Strike

Prime Contractor: RA NEMETZ

Sample Taken Date:

01/18/2024

Mix Design:

Unknown

Contractor: Unknown

Location: Marconi Bridge

Structure unique identifier:

Structure name:

Location of Pour:


The following testing has been tested in accordance with:

ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

SpecimenAverage diameter of cylinder (in)Cross sectional area of cylinder (in^2)Maximum load on cylinder (lb)Compressive strength of cylinder (psi)Type of fracture pattern of cylinder
13.9812.44465673743.01
24.0112.63450113564.01
34.0012.574519635971

DIME Test ID: 2024-01-18-12-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 3630
Age of specimen: 14 days
Certified By: Spencer Adams


ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

SpecimenAverage diameter of cylinder (in)Cross sectional area of cylinder (in^2)Maximum load on cylinder (lb)Compressive strength of cylinder (psi)Type of fracture pattern of cylinder
14.0212.69543344281.01
24.0112.63467403701.01
34.0112.634639136731

DIME Test ID: 2024-01-18-12-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 3890
Age of specimen: 28 days
Certified By: Spencer Adams



Summary of Items Observed and Conversations:

Comments: This report is for the purpose of reporting test results.
Should you require recommendations concerning repairs or remedial efforts please contact the METS representative,
who represents the Materials Engineering and Testing Services for your project.

*Subject to final inspection by the Resident Engineer.




TL- Report of Laboratory Testing