Project Information

Project ID: 995261 DEA: 072XJ804 EFIS: 0724000004 QA Service Level: 1
DIST-CO-RTE-PM: 07---
Work Description:
Location Description:
Contractor Name: POWELL CONSTRUCTORS INC
Contractor Address: 8555 BANANA AVE, FONTANA, CA 92335
Resident Engineer: Hai Hong Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-01-12-26
TL Number from the TL Form: 41977818
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 01/12/2024
Date that the sample was received by the laboratory/organization performing the testing: 01/17/2024
The quantity of what the sample constitutes: 130 CY
A brief description of the sample: 4X8 PCC cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 24-002
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Powell Constructors

Material Information

The concrete mix design number: 1610974
The truck number from where the sample was collected: 48052
The batch plant ticket number from where the sample was collected: 41977815
Concrete batch plant: NA
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: truck chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 4

DIME Test ID: 2024-01-12-26-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 01/19/2024
Date Tested: 01/19/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.01 in
Average diameter of cylinder 3 4.02 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.63 in^2
Cross sectional area of cylinder 3 12.69 in^2
Compressive strength (to nearest 10 psi) 3660 psi
Maximum load on cylinder 1 45085 lb
Maximum load on cylinder 2 48116 lb
Maximum load on cylinder 3 45726 lb
Compressive strength of cylinder 1 3569.7 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 3809.7 psi
Compressive strength of cylinder 3 3603.3 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours no data0 hours

Test 2 of 4

DIME Test ID: 2024-01-12-26-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 01/29/2024
Date Tested: 01/26/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.02 in
Average diameter of cylinder 2 4.01 in
Average diameter of cylinder 3 4.01 in
Cross sectional area of cylinder 1 12.69 in^2
Cross sectional area of cylinder 2 12.63 in^2
Cross sectional area of cylinder 3 12.63 in^2
Compressive strength (to nearest 10 psi) 5260 psi
Maximum load on cylinder 1 69504 lb
Maximum load on cylinder 2 61131 lb
Maximum load on cylinder 3 68872 lb
Compressive strength of cylinder 1 5477.1 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4840.1 psi
Compressive strength of cylinder 3 5453 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 14 days
Age of specimen in hours no data0 hours

Test 3 of 4

DIME Test ID: 2024-01-12-26-3
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 02/02/2024
Date Tested: 02/02/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.02 in
Average diameter of cylinder 3 4.01 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.69 in^2
Cross sectional area of cylinder 3 12.63 in^2
Compressive strength (to nearest 10 psi) 5850 psi
Maximum load on cylinder 1 69742 lb
Maximum load on cylinder 2 80169 lb
Maximum load on cylinder 3 72050 lb
Compressive strength of cylinder 1 5521.9 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 6317.5 psi
Compressive strength of cylinder 3 5704.7 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 21 days
Age of specimen in hours no data0 hours

Test 4 of 4

DIME Test ID: 2024-01-12-26-4
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 02/09/2024
Date Tested: 02/09/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.03 in
Average diameter of cylinder 2 4.04 in
Average diameter of cylinder 3 4.02 in
Cross sectional area of cylinder 1 12.76 in^2
Cross sectional area of cylinder 2 12.82 in^2
Cross sectional area of cylinder 3 12.69 in^2
Compressive strength (to nearest 10 psi) 6530 psi
Maximum load on cylinder 1 80670 lb
Maximum load on cylinder 2 86098 lb
Maximum load on cylinder 3 83211 lb
Compressive strength of cylinder 1 6322.1 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 6715.9 psi
Compressive strength of cylinder 3 6557.2 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours