Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993763 DEA: 101P0604 EFIS: 1022000065
QA Service Level: 1
DIST-CO-RTE-PM: 10-ALP/ALP-89-51.21/16.87
Work Description:
Location Description:
Contractor Name: Sinclair General Engineering
Contractor Address: PO Box 1453, Oakdale,CA 95361
Resident Engineer: Iqbal Aulakh Structure Rep.: Unknown
DIME Sample ID: 2024-01-08-42
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 341-3953
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 01/08/2024
Date that the sample was received by the laboratory/organization performing the testing: 01/09/2024
The quantity of what the sample constitutes: concrete cylinders
A brief description of the sample: 4x8 cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Outback Materials
The concrete mix design number: 85T3G49
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 152515
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-01-08-42-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 01/16/2024
Date Tested: 01/16/2024
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
5630 psi
|
|
Maximum load on cylinder 1
|
69840 lb
|
|
Maximum load on cylinder 2
|
71280 lb
|
|
Maximum load on cylinder 3
|
71350 lb
|
|
Compressive strength of cylinder 1
|
5556.1 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
5670.6 psi
|
|
Compressive strength of cylinder 3
|
5676.2 psi
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
8 days
|
|
Age of specimen in hours
|
no data0 hours
|