Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995083 DEA: 051R1604 EFIS: 0523000152
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-82.18, 82.2/82.2
Work Description: Repair high-load hit
Location Description: Near Santa Maria, US101 and Clark Ave overcrossing.
Contractor Name: SOUZA CONSTRUCTION
Contractor Address: 4027 Santa Fe Road, San Luis Obispo, CA 93403
Resident Engineer: Albert Reed Structure Rep.: Alis Chhay
DIME Sample ID: 2024-01-04-10
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 01/04/2024
Date that the sample was received by the laboratory/organization performing the testing: 01/05/2024
The quantity of what the sample constitutes: 2
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bridge Rubber Bearing
Mfg. Lot Number(s): 2527-11
Material/Compound/Elastomer ID: NA
Samples Representing: 2
Description (size): 1.15" x 8" x 18"
Comments:
Description (Number of Shims): 2
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Bridge Rubber Bearing
Batch Number: 135932
DIME Test ID: 2024-01-04-10-1
Test Method: ASTM D2240-15r21: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 01/09/2024
Date Tested: 01/08/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Temperature
|
72 f
|
|
Humidity
|
50 %
|
|
Reading #1
|
57
|
|
Reading #2
|
54
|
|
Reading #3
|
55
|
|
Reading #4
|
56
|
|
Reading #5
|
58
|
|
Mean
|
56
|
DIME Test ID: 2024-01-04-10-2
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 01/09/2024
Date Tested: 01/08/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of specimens tested
|
3
|
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
|
UTM
|
2kip
|
|
Humidity
|
50.00 %
|
|
Temperature
|
72 F
|
|
Sample 1 Median Thickness
|
0.086
|
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
|
Sample 1 Ultimate Tensile
|
2676.11 lbf/in^2
|
|
Sample 1 Elongation (350% Min)
|
Pass
|
|
Sample 2 Median Thickness
|
0.086
|
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
|
Sample 2 Ultimate Tensile
|
2628.61 lbf/in^2
|
|
Sample 2 Elongation (350% Min)
|
Pass
|
|
Sample 3 Median Thickness
|
0.089
|
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
|
Sample 3 Ultimate Tensile
|
2693.25 lbf/in^2
|
|
Sample 3 Elongation (350% Min)
|
Pass
|
|
Median of the Ultimate Tensile Values
|
2676.1 lbf/in^2
|
DIME Test ID: 2024-01-04-10-3
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 01/09/2024
Date Tested: 01/08/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of specimens tested
|
3
|
|
UTM
|
2kip
|
|
Humidity
|
50.00 %
|
|
Temperature
|
72 F
|
|
Sample 1 Median Thickness
|
0.086
|
|
Sample 1 Tear Strength
|
221.1
|
|
Sample 2 Median Thickness
|
0.085
|
|
Sample 2 Tear Strength
|
226.7
|
|
Sample 3 Median Thickness
|
0.086
|
|
Sample 3 Tear Strength
|
225.1
|
|
Median of the Tear Strength Values
|
225.1 lb/in
|
DIME Test ID: 2024-01-04-10-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 01/08/2024
Date Tested: 01/08/2024
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: