Print Report | Back to Sample Detail

Sample Record for 2024-01-02-11

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215425 DEA: 06360244 EFIS: 0613000005 QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-99-30.6/35.2
Work Description: Widen Freeway & Bridge Construction (Concrete Bridge)
Location Description:
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVE, SYLMAR, CA, 91342
Resident Engineer: Javier Huerta Structure Rep.: Ramandeep Guraya

Sample Information

DIME Sample ID: 2024-01-02-11
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Sample Organization Contact: 661-549-8281
Type of Sample: Quality Assurance
Type of Material: Soil
Sample Taken Date: 01/02/2024
Date that the sample was received by the laboratory/organization performing the testing: 01/02/2024
The quantity of what the sample constitutes: 2000 sq ft per CTM 231
A brief description of the sample: Class 2 Aggregate Base
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Jobsite

Material Information

The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Test holes at jobsite
Where the material sample would have been placed if not sampled:

Test Results

Test 1 of 1

DIME Test ID: 2024-01-02-11-1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Verified Date: 01/03/2024
Date Tested: 01/02/2024
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test: SB 99 #1 lane inside shoulder Sta 132+46 to 127+96 elevation: 0.95ft BFG width: 20.6 ft
Test Result Compliance: complies
Additional Comments When Verified:
Standard Count Density 1712 g/cc
Count or Density 1 803 g/cc
Count or Density 2 770 g/cc
Count or Density 3 821 g/cc
Count or Density 4 830 g/cc
Count or Density 5 749 g/cc
Standard Count Moisture 632 g/cc
Moisture Count 1 107 g/cc
Moisture Count 2 118 g/cc
Moisture Count 3 114 g/cc
Moisture Count 4 118 g/cc
Moisture Count 5 121 g/cc
Sum of Count or Density 3973.00 g/cc
Average of Count or Density 795.00 g/cc
Sum of Moisture Count 578.00 g/cc
Average of Moisture Count 116.00 g/cc
Count Ratio Density 0.46
Count Ratio Moisture 0.18
Calculated Percent Relative Compaction 97.4 %
Reported Percent Relative Compaction 97 %