Print Report | Back to Sample Detail

Sample Record for 2023-12-14-34

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995498 DEA: 072XL104 EFIS: 0724000158 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-10-14.23
Work Description: Column Casings Repair Work
Location Description:
Contractor Name: SECURITY PAVING COMPANY INC
Contractor Address: 13170 TELEFAIR AVE, SYLMAR, CA 91342
Resident Engineer: Sepand Minovi Structure Rep.: Suh Kwangsuk

Sample Information

DIME Sample ID: 2023-12-14-34
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 12/14/2023
Date that the sample was received by the laboratory/organization performing the testing: 12/18/2023
The quantity of what the sample constitutes: 1220
A brief description of the sample: Mechanical Coupler-Hoops
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Lawrence Street

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: CMC
Coupler Manufacturer: BarSplice
Intermediate Assembler or Fabricator:
Rebar Size: #4
Coupler Model: Double Barrel Zap Screwlok
Coating Standards: Uncoated
Shape of Rebar: Hoop
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): 3214
Rebar Heat Number(s): 4134664
Rebar Size 2 :
Coupler Unique ID: SB-17-02

Test Results

Test 1 of 2

DIME Test ID: 2023-12-14-34-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 01/19/2024
Date Tested: 12/20/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 4
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1140.201855492772Service SpliceA Auvinen
2140.201819390967Service SpliceA Auvinen
3140.201787789383Service SpliceA Auvinen
4140.201837191854Service SpliceA Auvinen
UTM 400KIP
Temperature 72 f

Test 2 of 2

DIME Test ID: 2023-12-14-34-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Verified Date: 01/19/2024
Date Tested: 12/28/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: 100 Cycle
Test Result Compliance:
Additional Comments When Verified:
Number of Samples Tested 1
SampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
5No. 4/13mm100.21850192503100 Cycleaauvinen
UTM 400kip
Temperature 72.00 f
Halo ID