Sample Record for 2023-12-18-11

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994109 DEA: 060W1704 EFIS: 0617000103 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-41-R27.4/R28.5
Work Description: REMOVE AC PAVEMENT, WIDEN TRAVEL WAY, AND CONSTRUCT RETAINING WALL.
Location Description: FRESNO COUNTY IN FRESNO FROM 0.1 MILE SOUTH OF ASHLAN AVENUE OVERCROSSING TO SHAW AVENUE OVERCROSSING
Contractor Name: RNR Construction, Inc
Contractor Address: 8589 Thys Court, Sacramento, CA,95828
Resident Engineer: Mark Mengoni Structure Rep.: Benjamin Holton

Sample Information

DIME Sample ID: 2023-12-18-11
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 341-3953
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 12/18/2023
Date that the sample was received by the laboratory/organization performing the testing: 12/19/2023
The quantity of what the sample constitutes: 300
A brief description of the sample: PCC cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Soil Nail Wall 3
The fabricator/manufacturer/facility name: Builders Concrete Ready Mix Plant Sanger

Material Information

The concrete mix design number: ND22023
The truck number from where the sample was collected: 6
The batch plant ticket number from where the sample was collected: 111335040
Concrete batch plant: Builders Concrete
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Wall 3 Wall Facing Station 28+70 to 31+20
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2023-12-18-11-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
Data has not been verified.

Test 2 of 2

DIME Test ID: 2023-12-18-11-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 01/16/2024
Date Tested: 01/16/2024
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 6190 psi
Maximum load on cylinder 1 76910 lb
Maximum load on cylinder 2 81160 lb
Maximum load on cylinder 3 75450 lb
Compressive strength of cylinder 1 6118.5 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 6456.6 psi
Compressive strength of cylinder 3 6002.4 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 29 days
Age of specimen in hours no data0 hours