Sample Record for 2023-11-29-28

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994226 DEA: 042K7004 EFIS: 0417000010 COOP: 042895 QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-880-R0.0/11.8
Work Description: Cold plane pavement and overlay with RHMA-G/RHMA-O (CAPITAL PREVENTIVE MAINTENANCE)
Location Description: ALAMEDA COUNTY IN FREMONT AND NEWARK FROM SANTA CLARA COUNTY LINE TO 0.4 MILE NORTH OF FREMONT BOULEVARD OVERCROSSING
Contractor Name: BAY CITIES PAVING & GRADING, INC.
Contractor Address: 1450 Civic Ct. BLDG B #400, Concord CA, 94520
Resident Engineer: Rodelio Baluyot Structure Rep.: Bettie C. "Betty" Geng

Sample Information

DIME Sample ID: 2023-11-29-28
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Hayward Field Laboratory
Sample Organization Contact: (510) 723-0168
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 11/29/2023
Date that the sample was received by the laboratory/organization performing the testing: 11/30/2023
The quantity of what the sample constitutes: 150 Tons
A brief description of the sample: 3/4 HMA + 25% RAP
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan-Pleasanton

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: D04 JMF 22 008

Test Results

Test 1 of 1

DIME Test ID: 2023-11-29-28-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/12/2023
Date Tested: 11/30/2023
Submitted By Organization: CT D04 - Hayward Field Laboratory
Organization Address: 21339 Cabot Boulevard,
Organization City: Hayward
Organization State: CA
Organization Zipcode: 94545
Organization Email: pamela.brown@dot.ca.gov
Organization Phone: (510) 385-8258
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2095.6 g
Corrected Asphalt Binder Content 4.47 %
Mass Loss 117.5 g
Correction Factor (Percent by mass of HMA Specimen) 1.00 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.13 %
Test Temperature 482 C