Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994084 DEA: 060U8804 EFIS: 0616000074
QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-99-26.3/27.6
Work Description: CONSTRUCT A NEW INTERCHANGE AT COMMERCIAL AVENUE NOW CALLED INTERNATIONAL AGRI-CENTER WAY
Location Description: ON STATE ROUTE 99
Contractor Name: SECURITY PAVING COMPANY INC
Contractor Address: 13170 TELEFAIR AVE, SYLMAR, CA 91342
Resident Engineer: Alberto Lopez Structure Rep.: Vicente Sanchez
DIME Sample ID: 2023-12-08-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 12/08/2023
Date that the sample was received by the laboratory/organization performing the testing: 12/12/2023
The quantity of what the sample constitutes: 186
A brief description of the sample: #9 5'-2" Welded Hoops
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RKR Steel Welding
Production or Authorization Testing: Authorization Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 1202054150
Hoop Manufacturer Lot Number(s): 1-2
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #9
Diameter of Hoop: 5'-2"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: NUCOR
Welding Company: RKR Steel Welding
Coating Standards: Uncoated
Weld Type: Flash Welded
DIME Test ID: 2023-12-08-3-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 12/28/2023
Date Tested: 12/19/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Samples
|
6
|
| Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | | 1 | 1 | 9 | 1 | 92997.39 | 92997 | Ok Necking | A Auvinen | | 2 | 1 | 9 | 1 | 92705.50 | 92705 | Ok Necking | A Auvinen | | 3 | 1 | 9 | 1 | 92228.52 | 92229 | Ok Necking | A Auvinen | | 1 | 2 | 9 | 1 | 92340.01 | 92340 | Ok Necking | A Auvinen | | 2 | 2 | 9 | 1 | 92119.98 | 92120 | Ok Necking | A Auvinen | | 3 | 2 | 9 | 1 | 93377.25 | 93377 | Ok Necking | A Auvinen |
| |
|
UTM
|
400KIP
|
|
Temperature
|
72 f
|