Sample Record for 2023-11-13-87
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994820 DEA: 060V1104 EFIS: 0616000208
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE,KIN-5,41,198-Var
Work Description: STRATFORD KINGS RIVER BRIDGE REPLACEMENT.
Location Description: FRESNO AND KINGS COUNTIES AT VARIOUS LOCATIONS
Contractor Name: M.C.M. Construction, INC. (Richard McCall)
Contractor Address: 6413 32nd Street, North Highlands, Ca 95660
Resident Engineer: Din Dadawalla Structure Rep.: Martin Garcia
Sample Information
DIME Sample ID: 2023-11-13-87
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 11/13/2023
Date that the sample was received by the laboratory/organization performing the testing: 11/15/2023
The quantity of what the sample constitutes: 155
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bridge Rubber Bearing
Material Information
Mfg. Lot Number(s): 2527-11
Material/Compound/Elastomer ID: NA
Samples Representing: 155
Description (size): 1.73" x 12" x 24"
Comments:
Description (Number of Shims): 3
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Bridge Rubber Bearing
Batch Number: 135932
Test Results
Test 1 of 4
DIME Test ID: 2023-11-13-87-1
Test Method: ASTM D2240-15r21: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 12/18/2023
Date Tested: 12/07/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Temperature
|
72 f
|
|
Humidity
|
50 %
|
|
Reading #1
|
50
|
|
Reading #2
|
50
|
|
Reading #3
|
50
|
|
Reading #4
|
51
|
|
Reading #5
|
50
|
|
Mean
|
50.2
|
Test 2 of 4
DIME Test ID: 2023-11-13-87-2
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 12/18/2023
Date Tested: 12/07/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of specimens tested
|
3
|
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
|
UTM
|
2kip
|
|
Humidity
|
50.00 %
|
|
Temperature
|
72 F
|
|
Sample 1 Median Thickness
|
0.076
|
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
|
Sample 1 Ultimate Tensile
|
2423.56 lbf/in^2
|
|
Sample 1 Elongation (350% Min)
|
Pass
|
|
Sample 2 Median Thickness
|
0.077
|
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
|
Sample 2 Ultimate Tensile
|
2391.98 lbf/in^2
|
|
Sample 2 Elongation (350% Min)
|
Pass
|
|
Sample 3 Median Thickness
|
0.079
|
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
|
Sample 3 Ultimate Tensile
|
2369.04 lbf/in^2
|
|
Sample 3 Elongation (350% Min)
|
Pass
|
|
Median of the Ultimate Tensile Values
|
2392 lbf/in^2
|
Test 3 of 4
DIME Test ID: 2023-11-13-87-3
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 12/18/2023
Date Tested: 12/07/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of specimens tested
|
3
|
|
UTM
|
2kip
|
|
Humidity
|
50.00 %
|
|
Temperature
|
72 F
|
|
Sample 1 Median Thickness
|
0.083
|
|
Sample 1 Tear Strength
|
232.8
|
|
Sample 2 Median Thickness
|
0.083
|
|
Sample 2 Tear Strength
|
220.8
|
|
Sample 3 Median Thickness
|
0.085
|
|
Sample 3 Tear Strength
|
219.3
|
|
Median of the Tear Strength Values
|
220.8 lb/in
|
Test 4 of 4
DIME Test ID: 2023-11-13-87-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 12/14/2023
Date Tested: 12/14/2023
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: