Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214486 DEA: 080K1224 EFIS: 0815000244
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-R28.6/37.5
Work Description: REHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT
Location Description: SAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING
Contractor Name: SULLY - MILLER CONTRACTING COMPANY
Contractor Address: 135 S STATE COLLEGE BLVD. 400, BREA, CA 92821
Resident Engineer: Larry J Canuti Structure Rep.: Taghreed Al-khateeb
DIME Sample ID: 2023-11-14-66
TL Number from the TL Form: 1042-1114
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 11/14/2023
Date that the sample was received by the laboratory/organization performing the testing: 11/14/2023
The quantity of what the sample constitutes: 6
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 1042-1114
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SULLY Miller
The concrete mix design number: G3-22-PCC-273
The truck number from where the sample was collected: Not Provided on TL
The batch plant ticket number from where the sample was collected: 21
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: SB I15 STAGE 2A JPCP LN 1STA 131.65 - 131.45
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2023-11-14-66-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521 Cured in accordance with ASTM C511
Verified Date: 12/26/2023
Date Tested: 12/26/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With density determined by dimension measurements
|
|
Average cylinder density (to nearest 1 pcf)
|
148 lb/ft^3
|
|
Average diameter of cylinder 1
|
5.99 in
|
|
Average diameter of cylinder 2
|
5.98 in
|
|
Average diameter of cylinder 3
|
5.99 in
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|