Print Report | Back to Sample Detail

Sample Record for 2023-10-09-84

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994803 DEA: 043J0704 EFIS: 0415000077 QA Service Level: 1
DIST-CO-RTE-PM: 04-CC-80-10.1/13.5
Work Description: Remove PCC and AC, place PCP and AC Resurfacing.
Location Description: Construction on State Highway in Contra Costa County in Hercules and Crockett from Route 80/4 separation to 0.1 mile west of Crockett Viaduct.
Contractor Name: VANGUARD CONSTRUCTION, INC.
Contractor Address: 651 ENTERPRISE CT, LIVERMORE, CA 94550
Resident Engineer: Ta Seng Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-10-09-84
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Richmond Field Laboratory
Sample Organization Contact: (510) 231-7151
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/09/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/16/2023
The quantity of what the sample constitutes: Production Start-Up
A brief description of the sample: 1/2-INCH HMA-SP Type A
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: County Asphalt Batch Plant

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number: 1
Sublot number: 1
HMA Mix Number: L230620

Test Results

Test 1 of 1

DIME Test ID: 2023-10-09-84-5
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 11/28/2023
Date Tested: 10/16/2023
Submitted By Organization: CT D04 - Richmond Field Laboratory
Organization Address: 3401 Regatta Boulevard,
Organization City: Richmond
Organization State: CA
Organization Zipcode: 94508
Organization Email: santiago.sequeira@dot.ca.gov
Organization Phone: (510) 385-7641
General Comments for this Test: Production Start-Up County Asphalt Batch Plant Theoretical Maximum Density = 2.600
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 2
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Specific Gravity for Sample 1 2.615
Specific Gravity for Sample 2 2.615
Average Specific Gravity 2.615
Theoretical maximum density at 25°C (77°F) 2 kg/m^3

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2023-10-09-84-1AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)11/28/2023Not scheduledIGNACIO ARECHIGACT D04 - Richmond Field LaboratoryProduction Start-Up County Asphalt Batch Plant
2023-10-09-84-2AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)11/28/2023Not scheduledIGNACIO ARECHIGACT D04 - Richmond Field LaboratoryProduction Start-Up County Asphalt Batch Plant
2023-10-09-84-3AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)11/28/2023Not scheduledIGNACIO ARECHIGACT D04 - Richmond Field LaboratoryProduction Start-Up County Asphalt Batch Plant
2023-10-09-84-4AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)11/28/2023Not scheduledIGNACIO ARECHIGACT D04 - Richmond Field LaboratoryProduction Start-Up County Asphalt Batch Plant RAP BURN