Print Report | Back to Sample Detail

Sample Record for 2023-11-20-16

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-11-20-16
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 11/20/2023
Date that the sample was received by the laboratory/organization performing the testing: 11/21/2023
The quantity of what the sample constitutes: 10
A brief description of the sample: Ductile Iron Casting
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SDI

Material Information

Heat Number (s): I213 I263 H023 K023 I143 J113 J123 J263 J193
Part Number (s): 12 6 PC BP 12 6 PC BP 12 6 PC BP 19 6 PC BP 2
Material Specification: A536
Grades: 80-55-06
Metal Foundry Manufacturer (Mill): Farrar Corporation
Prestressing Manufacturer: SDI

Test Results

Test 1 of 1

DIME Test ID: 2023-11-20-16-1
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 01/02/2024
Date Tested: 12/05/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 10
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
I2130.50.19635637971057856aauvinen
K0230.4990.19556631121108638.5aauvinen
I2630.50.19635639891127309.9aauvinen
I1430.50.19635646151130929.3aauvinen
H0230.50.19635630211115189.6aauvinen
J1130.50.19635649761137888.8aauvinen
J1230.50.19635634731107338.8aauvinen
J2630.50.196356523211468910.6aauvinen
I2730.50.19635624541102059.7aauvinen
J1930.4990.19556628221093539.7aauvinen
UTM 67kip
Temperature 72 F