Print Report | Back to Sample Detail

Sample Record for 2023-10-09-75

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214337 DEA: 080E33U4 EFIS: 0817000075 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-115-R7.3/R10.0
Work Description: ADD WB AUX & EB DECEL LANES, WIDEN I15 SW CONNECT,RAMPS/BRDG
Location Description: SAN BERNARDINO COUNTY IN ONTARIO FROM 0.2 MILE WEST OF CUCAMONGA CREEK BRIDGE TO MILLIKEN AVENUE
Contractor Name: Ames Construction
Contractor Address: 391 North Main Street, Suite 302, Corona, CA 92880
Resident Engineer: Denise Sostrom Structure Rep.: Matt Bruce

Sample Information

DIME Sample ID: 2023-10-09-75
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 10/09/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/11/2023
The quantity of what the sample constitutes: 12 Beams
A brief description of the sample: Rapid Set Concrete beams
From where was the sample collected: Job Site
Laboratory sample identification: R3-A1, R3-A2, R3-A3, R3-B1, R3-B2, R2-B3, R3-C1, R3-C2, R3-C3, R3-D1, R3-D2, R3-D3
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Robertson's Ready Mix - Fontana

Material Information

The concrete mix design number: LB0608SP
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 7968052
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: back of concrete truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 16

DIME Test ID: 2023-10-09-75-1
Test Method: CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement Concrete
Verified Date: 11/17/2023
Date Tested: 10/09/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Set A
Test Result Compliance:
Additional Comments When Verified:
Ball penetration in freshly mixed concrete (average) 4 inch

Test 2 of 16

DIME Test ID: 2023-10-09-75-2
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 11/17/2023
Date Tested: 10/09/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Set A
Test Result Compliance:
Additional Comments When Verified:
Air Content 1.6 %

Test 3 of 16

DIME Test ID: 2023-10-09-75-3
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Verified Date: 11/17/2023
Date Tested: 10/09/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: CC not included. Set A
Test Result Compliance:
Additional Comments When Verified:
Unit weight of the concrete 145.9 lb/ft^3
Cement content 0 lb/yd^3

Test 4 of 16

DIME Test ID: 2023-10-09-75-4
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 11/17/2023
Date Tested: 10/20/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Set A
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens 3
Does the testing machine measure load or stress on the beam specimen? Load
Fracture initiates in the tension surface Within the Middle Third of the Span Length
Fracture occurred at a capped section No
Is a beam dimensional correction factor used? No
Age of specimen 10 days
Modulus of rupture 770 psi
Modulus of rupture 2 810 psi
Modulus of rupture average 780 psi
Modulus of rupture 3 770 psi

Test 5 of 16

DIME Test ID: 2023-10-09-75-5
Test Method: CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement Concrete
Verified Date: 11/17/2023
Date Tested: 10/09/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Set B
Test Result Compliance:
Additional Comments When Verified:
Ball penetration in freshly mixed concrete (average) 2.25 inch

Test 6 of 16

DIME Test ID: 2023-10-09-75-6
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 11/17/2023
Date Tested: 10/09/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Set B
Test Result Compliance:
Additional Comments When Verified:
Air Content 2.2 %

Test 7 of 16

DIME Test ID: 2023-10-09-75-7
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Verified Date: 11/17/2023
Date Tested: 10/09/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: CC not included. Set B
Test Result Compliance:
Additional Comments When Verified:
Unit weight of the concrete 146.5 lb/ft^3
Cement content 0 lb/yd^3

Test 8 of 16

DIME Test ID: 2023-10-09-75-8
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 11/17/2023
Date Tested: 10/20/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Set B
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens 3
Does the testing machine measure load or stress on the beam specimen? Load
Fracture initiates in the tension surface Within the Middle Third of the Span Length
Fracture occurred at a capped section No
Is a beam dimensional correction factor used? No
Age of specimen 10 days
Modulus of rupture 710 psi
Modulus of rupture 2 760 psi
Modulus of rupture average 730 psi
Modulus of rupture 3 730 psi

Test 9 of 16

DIME Test ID: 2023-10-09-75-9
Test Method: CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement Concrete
Verified Date: 11/17/2023
Date Tested: 10/10/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Set C
Test Result Compliance:
Additional Comments When Verified:
Ball penetration in freshly mixed concrete (average) 3.25 inch

Test 10 of 16

DIME Test ID: 2023-10-09-75-10
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 11/17/2023
Date Tested: 10/10/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Set C
Test Result Compliance:
Additional Comments When Verified:
Air Content 1.7 %

Test 11 of 16

DIME Test ID: 2023-10-09-75-11
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Verified Date: 11/17/2023
Date Tested: 10/10/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: CC not included. Set C
Test Result Compliance:
Additional Comments When Verified:
Unit weight of the concrete 146.8 lb/ft^3
Cement content 0 lb/yd^3

Test 12 of 16

DIME Test ID: 2023-10-09-75-12
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 11/17/2023
Date Tested: 10/20/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Set C
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens 3
Does the testing machine measure load or stress on the beam specimen? Load
Fracture initiates in the tension surface Within the Middle Third of the Span Length
Fracture occurred at a capped section No
Is a beam dimensional correction factor used? No
Age of specimen 10 days
Modulus of rupture 770 psi
Modulus of rupture 2 700 psi
Modulus of rupture average 730 psi
Modulus of rupture 3 730 psi

Test 13 of 16

DIME Test ID: 2023-10-09-75-13
Test Method: CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement Concrete
Verified Date: 11/17/2023
Date Tested: 10/10/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Set D
Test Result Compliance:
Additional Comments When Verified:
Ball penetration in freshly mixed concrete (average) 3.5 inch

Test 14 of 16

DIME Test ID: 2023-10-09-75-14
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 11/17/2023
Date Tested: 10/10/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Set D
Test Result Compliance:
Additional Comments When Verified:
Air Content 1.5 %

Test 15 of 16

DIME Test ID: 2023-10-09-75-15
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Verified Date: 11/17/2023
Date Tested: 10/10/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: CC not included. Set D
Test Result Compliance:
Additional Comments When Verified:
Unit weight of the concrete 145.1 lb/ft^3
Cement content 0 lb/yd^3

Test 16 of 16

DIME Test ID: 2023-10-09-75-16
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 11/17/2023
Date Tested: 10/20/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Set D
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens 3
Does the testing machine measure load or stress on the beam specimen? Load
Fracture initiates in the tension surface Within the Middle Third of the Span Length
Fracture occurred at a capped section No
Is a beam dimensional correction factor used? No
Age of specimen 10 days
Modulus of rupture 730 psi
Modulus of rupture 2 730 psi
Modulus of rupture average 740 psi
Modulus of rupture 3 750 psi