Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215425 DEA: 06360244 EFIS: 0613000005
QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-99-30.6/35.2
Work Description: Widen Freeway & Bridge Construction (Concrete Bridge)
Location Description:
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVE, SYLMAR, CA, 91342
Resident Engineer: Javier Huerta Structure Rep.: Ramandeep Guraya
DIME Sample ID: 2023-04-18-150
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Visalia Field Laboratory
Sample Organization Contact: (559) 974-1304
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/18/2023
Date that the sample was received by the laboratory/organization performing the testing: 04/19/2023
The quantity of what the sample constitutes: 9 CY
A brief description of the sample: Type II/V Concrete Cement Agg
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: 06-Tul 99 J St Bridge
The fabricator/manufacturer/facility name: CalPort Tul Plant
The concrete mix design number: 85Q41SOP
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 125910
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of the concrete truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2023-04-18-150-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/15/2023
Date Tested: 05/16/2023
Submitted By Organization: CT D06 - Visalia Field Laboratory
Organization Address: 8530 W Roosevelt Ave,
Organization City: Visalia
Organization State: CA
Organization Zipcode: 93291
Organization Email: paul.klinker@dot.ca.gov
Organization Phone: (559) 974-1304
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
7580 psi
|
|
Maximum load on cylinder 1
|
93357 lb
|
|
Maximum load on cylinder 2
|
92587 lb
|
|
Maximum load on cylinder 3
|
99703 lb
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|
DIME Test ID: 2023-04-18-150-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/15/2023
Date Tested: 05/16/2023
Submitted By Organization: CT D06 - Visalia Field Laboratory
Organization Address: 8530 W Roosevelt Ave,
Organization City: Visalia
Organization State: CA
Organization Zipcode: 93291
Organization Email: paul.klinker@dot.ca.gov
Organization Phone: (559) 974-1304
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
7320 psi
|
|
Maximum load on cylinder 1
|
91758 lb
|
|
Maximum load on cylinder 2
|
94865 lb
|
|
Maximum load on cylinder 3
|
89394 lb
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|