Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215425 DEA: 06360244 EFIS: 0613000005
QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-99-30.6/35.2
Work Description: Widen Freeway & Bridge Construction (Concrete Bridge)
Location Description:
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVE, SYLMAR, CA, 91342
Resident Engineer: Javier Huerta Structure Rep.: Ramandeep Guraya
DIME Sample ID: 2023-07-20-91
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Visalia Field Laboratory
Sample Organization Contact: (559) 341-4165
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/20/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/21/2023
The quantity of what the sample constitutes: 9.5 CY
A brief description of the sample: type II/V Concrete Cement
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: 06-Tul 99 J St -Ave 264
The fabricator/manufacturer/facility name: Calport Tul
The concrete mix design number: 85Q41SOP
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Job site
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2023-07-20-91-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/14/2023
Date Tested: 08/17/2023
Submitted By Organization: CT D06 - Visalia Field Laboratory
Organization Address: 8530 West Roosevelt Avenue,
Organization City: Visalia
Organization State: CA
Organization Zipcode: 93291
Organization Email: shoaib.ahmed@dot.ca.gov
Organization Phone: (559) 341-4165
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
5950 psi
|
Maximum load on cylinder 1
|
73442 lb
|
Maximum load on cylinder 2
|
75865 lb
|
Maximum load on cylinder 3
|
75221 lb
|
Type of fracture pattern of cylinder 1
|
2
|
Type of fracture pattern of cylinder 2
|
3
|
Type of fracture pattern of cylinder 3
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
0 hours
|