Project ID: 994405 DEA: 080F5414 EFIS: 0800000137 COOP: 081743
QA Service Level: 2
DIST-CO-RTE-PM: 08-RIV--
Work Description: RIV 71/91 FLYOVER
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Mohsen Javaherneshan Structure Rep.: Anton Schmieder
DIME Sample ID: 2023-09-21-107
TL Number from the TL Form:
Sample Submitted By Organization: Surecast West
Sample Organization Contact: (951) 491-9506
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 09/21/2023
Date that the sample was received by the laboratory/organization performing the testing: 11/14/2023
The quantity of what the sample constitutes: 9 CY
A brief description of the sample: type II/V Cement
From where was the sample collected: Job Site
Laboratory sample identification: 30935694
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex Redlands
The concrete mix design number: 1610974
The truck number from where the sample was collected: LOAD 1
The batch plant ticket number from where the sample was collected: 30935694
Concrete batch plant: Redlands
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: concrete sample from whheelbarrow
Where the material sample would have been placed if not sampled: mse wall 420
From Lot No.:
Bag Lot No.:
DIME Test ID: 2023-09-21-107-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Submitted By Organization: Surecast West
Organization Address: 8203 Alabama Street,
Organization City: Redlands
Organization State: CA
Organization Zipcode: 92373
Organization Email: cody@surecastwest.com
Organization Phone: (951) 491-9506
Data has not been verified.
DIME Test ID: 2023-09-21-107-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/14/2023
Date Tested: 11/14/2023
Submitted By Organization: Surecast West
Organization Address: 8203 Alabama Street,
Organization City: Redlands
Organization State: CA
Organization Zipcode: 92373
Organization Email: cody@surecastwest.com
Organization Phone: (951) 491-9506
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
6335 psi
|
Maximum load on cylinder 1
|
180510 lb
|
Maximum load on cylinder 2
|
178910 lb
|
Type of fracture pattern of cylinder 1
|
1
|
Type of fracture pattern of cylinder 2
|
1
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
54 days
|
Age of specimen in hours
|
0 hours
|