Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215425 DEA: 06360244 EFIS: 0613000005
QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-99-30.6/35.2
Work Description: Widen Freeway & Bridge Construction (Concrete Bridge)
Location Description:
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVE, SYLMAR, CA, 91342
Resident Engineer: Javier Huerta Structure Rep.: Ramandeep Guraya
DIME Sample ID: 2023-10-30-62
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Visalia Field Laboratory
Sample Organization Contact: (559) 341-4165
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 10/30/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/30/2023
The quantity of what the sample constitutes: 1088 Tons
A brief description of the sample: 3/4" HMA -A R15% PG 64-10
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Porterville Rock and Recycle PAI
Source Identification (SMARA, name of Pit or Job Site): 0613000005
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Conveyor Belt
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number: 5
Sublot number: 19
Aggregate Mix Number:
DIME Test ID: 2023-10-30-62-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 11/08/2023
Date Tested: 10/30/2023
Submitted By Organization: CT D06 - Visalia Field Laboratory
Organization Address: 8530 West Roosevelt Avenue,
Organization City: Visalia
Organization State: CA
Organization Zipcode: 93291
Organization Email: shoaib.ahmed@dot.ca.gov
Organization Phone: (559) 341-4165
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested?
|
Combined Gradation
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
Cumulative percent passing the 1/2 in. sieve
|
83 %
|
Cumulative percent passing the 3/8 in. sieve
|
67 %
|
Cumulative percent passing the #4 sieve
|
44 %
|
Cumulative percent passing the #8 sieve
|
30 %
|
Cumulative percent passing the #16 sieve
|
21 %
|
Cumulative percent passing the #30 sieve
|
14 %
|
Cumulative percent passing the #50 sieve
|
10 %
|
Cumulative percent passing the #100 sieve
|
7 %
|
Cumulative percent passing the #200 sieve
|
5.4 %
|
DIME Test ID: 2023-10-30-62-2
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 11/08/2023
Date Tested: 10/30/2023
Submitted By Organization: CT D06 - Visalia Field Laboratory
Organization Address: 8530 West Roosevelt Avenue,
Organization City: Visalia
Organization State: CA
Organization Zipcode: 93291
Organization Email: shoaib.ahmed@dot.ca.gov
Organization Phone: (559) 341-4165
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2023-10-30-62-3
Test Method: AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)
Verified Date: 11/08/2023
Date Tested: 10/30/2023
Submitted By Organization: CT D06 - Visalia Field Laboratory
Organization Address: 8530 West Roosevelt Avenue,
Organization City: Visalia
Organization State: CA
Organization Zipcode: 93291
Organization Email: shoaib.ahmed@dot.ca.gov
Organization Phone: (559) 341-4165
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Which test procedure(s) is/are used?
|
Procedure A and Procedure B
|
Was strict temperature control maintained?
|
No
|
What type of water was used?
|
Distilled
|
Durability Index (coarse)
|
82
|
Durability Index (fine)
|
61
|