Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 033J2304 Cty SAC Rte 5 PM 26.9 Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Unknown |
Date Reported: |
11/30/2023 |
|
|
Address: |
TL Number: |
294751 |
||
|
City: |
||||
|
Project Name: REMOVE UNEVEN PAVEMENT ON RAMP & INSTALL APPROACH SLABS. |
||||
|
Prime Contractor: FBD VANGUARD CONSTRUCTION, INC. |
||||
|
Sample Taken Date: |
11/02/2023 |
Mix Design: |
Unknown |
|
|
Contractor: Unknown |
Location : SACRAMENTO COUNTY IN SACRAMENTO AT SAN JUAN ROAD UNDERCROSSING |
|||
|
Structure unique identifier: |
||||
|
Structure name: |
||||
|
Location of Pour: |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.00 | 12.57 | 89557 | 7127.0 | 2 |
| 2 | 4.02 | 12.69 | 97350 | 7670.0 | 4 |
| 3 | 4.01 | 12.63 | 83643 | 6623 | 1 |
DIME Test ID: 2023-11-02-17-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 7140
Age of specimen: 28 days
Certified By: Spencer Adams
|
*Subject to final inspection by the Resident Engineer. |
|
TL- Report of Laboratory Testing