Print Report | Back to Sample Detail

Sample Record for 2023-09-11-80

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994812 DEA: 042K7204 EFIS: 0417000014 QA Service Level: 1
DIST-CO-RTE-PM: 04-CC-4-R14.3/24.3
Work Description: Pvmt rehabilitation, slab repl, ADA curb ramp and install guardrail.
Location Description: On state highway in Contra Costa County in and near Concord and Pittsburg from 0.3 miles east of Peralta Road Undercrossing to Loveridge Road Overcrossing.
Contractor Name: O.C. Jones & Sons, Inc. (Victor Babbitt)
Contractor Address: 1520 Fourth Street, Berkeley, CA 94710
Resident Engineer: Rabi Mukherjee Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-09-11-80
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 09/11/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/02/2023
The quantity of what the sample constitutes: 5270g
A brief description of the sample: 3/4-Inch HMA - SP Type A PG 58-22VL
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Pleasanton Drier Drum

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-01-0010
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Sample Pickup From Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number: 3923

Test Results

Test 1 of 2

DIME Test ID: 2023-09-11-80-3
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 10/25/2023
Date Tested: 10/02/2023
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: Clay Reading=4.6 Sand Reading=3.8 S.E.=83 Test PASSED
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 83

Test 2 of 2

DIME Test ID: 2023-09-11-80-4
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 10/25/2023
Date Tested: 10/02/2023
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: Virgin Results 3/4=15 1/2=790 3/8=1520 4=2635 8=265 16=355 30=402 50=433 100=453 200=464
Test Result Compliance: does not comply
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve no data0 %
Cumulative percent passing the 1 1/2 in. sieve no data0 %
Cumulative percent passing the 1 in. sieve no data0 %
Cumulative percent passing the 3/4 in. sieve no data0 %
Cumulative percent passing the 1/2 in. sieve no data0 %
Cumulative percent passing the 3/8 in. sieve 5 %
Cumulative percent passing the #4 sieve 650 %
Cumulative percent passing the #8 sieve 181 %
Cumulative percent passing the #16 sieve 244 %
Cumulative percent passing the #30 sieve 277 %
Cumulative percent passing the #50 sieve 309 %
Cumulative percent passing the #100 sieve 337 %
Cumulative percent passing the #200 sieve 356 %

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2023-09-11-80-1AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)10/25/2023Not scheduledIGNACIO ARECHIGACT D04 - Concord Field LaboratoryClay Reading=4.4 Sand Reading=3.8 S.E.=87 Sample #1 Granite Pleasanton Drier Drum Plant Test PASSED
2023-09-11-80-2AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)10/25/2023Not scheduledIGNACIO ARECHIGACT D04 - Concord Field LaboratoryVirgin Results 3/4=50 1/2=845 3/8=1665 4=3075 8=280 16=357 30=400 50=433 100=456 200=469