Print Report | Back to Sample Detail

Sample Record for 2023-10-12-46

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993742 DEA: 07321804 EFIS: 0716000052 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-405-7.0/12.9
Work Description: PLACE MINOR CONCRETE AND HOT MIX ASPHALT.
Location Description: LOS ANGELES COUNTY IN AND NEAR LONG BEACH, CARSON AND LOS ANGELES AT VARIOUS LOCATIONS FROM 0.1 MILE NORTH OF ROUTE 710 TO ROUTE 110/405 SEPARATION
Contractor Name: WESTCOAST PUBLIC WORKS INC.
Contractor Address: Unknown
Resident Engineer: Samuel Gallardo Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-10-12-46
TL Number from the TL Form: 924634A
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/12/2023
Date that the sample was received by the laboratory/organization performing the testing: 09/15/2023
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/4" WMA-A 103793
From where was the sample collected: Manufacturer
Laboratory sample identification: 23-437
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA Corona

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 103793
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 2

DIME Test ID: 2023-10-12-46-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/23/2023
Date Tested: 09/18/2023
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7359.3 grams
Mass of oven-dry sample in air for Sample 1 2534.8 grams
Mass of container filled with the sample and water for Sample 1 8890.4 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.525
Theoretical maximum density at 25°C (77°F) 157.2 lb/ft^3

Test 2 of 2

DIME Test ID: 2023-10-12-46-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/23/2023
Date Tested: 09/18/2023
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4023.4 g
Mass of the specimen and specimen basket assembly prior to ignition 6179.9 g
Mass of HMA Sample prior to ignition 2156.5 g
Corrected Asphalt Binder Content 4.75 %
Mass Loss 107.7 g
Mass of aggregate remaining after ignition 2048.8 g
Correction Factor (Percent by mass of HMA Specimen) 0.24 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C