Project Information

Project ID: 994803 DEA: 043J0704 EFIS: 0415000077 QA Service Level: 1
DIST-CO-RTE-PM: 04-CC-80-10.1/13.5
Work Description: Remove PCC and AC, place PCP and AC Resurfacing.
Location Description: Construction on State Highway in Contra Costa County in Hercules and Crockett from Route 80/4 separation to 0.1 mile west of Crockett Viaduct.
Contractor Name: VANGUARD CONSTRUCTION, INC.
Contractor Address: 651 ENTERPRISE CT, LIVERMORE, CA 94550
Resident Engineer: Ta Seng Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-09-30-36
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Richmond Field Laboratory
Sample Organization Contact: (510) 231-7151
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 09/30/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/10/2023
The quantity of what the sample constitutes: Flexural Strength PCC Beam
A brief description of the sample: PCC Beams
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vanguard Mobile Hercules Plant

Material Information

The concrete mix design number: HE4x4BM
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: none
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2023-09-30-36-4
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 10/19/2023
Date Tested: 10/10/2023
Submitted By Organization: CT D04 - Richmond Field Laboratory
Organization Address: 3401 Regatta Boulevard,
Organization City: Richmond
Organization State: CA
Organization Zipcode: 94508
Organization Email: santiago.sequeira@dot.ca.gov
Organization Phone: (510) 385-7641
General Comments for this Test: Vanguard Mobile Hercules Plant Beam PASSED Beam Set 4
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens 1
Does the testing machine measure load or stress on the beam specimen? Stress
Fracture initiates in the tension surface Within the Middle Third of the Span Length
Fracture occurred at a capped section Yes
Is a beam dimensional correction factor used? Yes
Age of specimen 10 days
Modulus of rupture 700 psi

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2023-09-30-36-1CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete10/19/2023Not scheduledIGNACIO ARECHIGACT D04 - Richmond Field LaboratoryVanguard Mobile Hercules Plant Beams PASSED Beam Set 1
2023-09-30-36-2CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete10/19/2023Not scheduledIGNACIO ARECHIGACT D04 - Richmond Field LaboratoryVanguard Mobile Hercules Plant Beams PASSED Beam Set 2
2023-09-30-36-3CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete10/19/2023Not scheduledIGNACIO ARECHIGACT D04 - Richmond Field LaboratoryVanguard Mobile Hercules Plant Beams PASSED Beam Set 3