Project Information

Project ID: 994330 DEA: 09366404 EFIS: 0916000006 QA Service Level: 1
DIST-CO-RTE-PM: 09-MNO-395-58.2/60.4
Work Description: HOT MIX ASPHALT (TYPE A), IMPORTED BORROW, AND ROADWAY EXCAVATION.
Location Description: MONO COUNTY ABOUT 6 MILES NORTH OF LEE VINING FROM ROUTE 167 TO 0.4 MILE NORTH OF CONWAY RANCH ROAD
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 500 South Main Street, Bishop, CA 93514
Resident Engineer: David Carruba Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-10-17-26
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 10/17/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/18/2023
The quantity of what the sample constitutes: 13 Cubic Yards / Mammoth Ready Mix
A brief description of the sample: 5000 Psi Mix / Mammoth
From where was the sample collected: Job Site
Laboratory sample identification: Conc-04
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mammoth Ready Mix

Material Information

The concrete mix design number: 1304.18.25.A
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 58900
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: DS-1 Headwall Inlet
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2023-10-17-26-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/23/2023
Date Tested: 10/23/2023
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: DS-1 Headwall Inlet
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? no data
Apparent mass of submerged cylinder 1 3.5 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 3530 psi
Maximum load on cylinder 1 43390 lb
Maximum load on cylinder 2 44900 lb
Maximum load on cylinder 3 44750 lb
Compressive strength of cylinder 1 3450.0 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 3570.0 psi
Compressive strength of cylinder 3 3560 psi
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 6 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test 2 of 2

DIME Test ID: 2023-10-17-26-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 11/14/2023
Date Tested: 11/14/2023
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: PCC-04
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? no data
Apparent mass of submerged cylinder 1 3.5 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 5200 psi
Maximum load on cylinder 1 64955 lb
Maximum load on cylinder 2 64740 lb
Maximum load on cylinder 3 66285 lb
Compressive strength of cylinder 1 5170.0 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 5150.0 psi
Compressive strength of cylinder 3 5270 psi
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen no data0 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2023-10-17-26-3ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens10/19/202311/28/2023Jeffery PuenteCT D09 - Bishop Field LaboratoryDerek Carrington