Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215240 DEA: 021H6804 EFIS: 0216000010
QA Service Level: 1
DIST-CO-RTE-PM: 02-TEH-5-39/41.9
Work Description: SB Cottonwood Scales
Location Description:
Contractor Name: McCuen Construction, Inc.
Contractor Address: 3269 Swetzer Road, Loomis, CA,95690
Resident Engineer: Edward Worden Structure Rep.: Chris Brace
DIME Sample ID: 2023-10-09-30
TL Number from the TL Form: 853406
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/09/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/09/2023
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: 16 boxes of Lime Treated 1/2-inch Type A HMA (eq. PG 64-28 M) with 25.0% RAP and virgin PG 58-34 M binder from Valero (Benicia, CA)
From where was the sample collected: Manufacturer
Laboratory sample identification: D79370
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tullis - Northstate Asphalt (Redding, CA)
DIME Test ID: 2023-10-09-30-1
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 10/26/2023
Date Tested: 10/17/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: S1=101 PSI, S2=94 PSI, TSR=93%
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
101 psi
|
|
Average Wet Tensile Strength
|
94 psi
|
|
Tensile Strength Ratio
|
0.93
|
DIME Test ID: 2023-10-09-30-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 10/26/2023
Date Tested: 10/17/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pa=3.9%
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
3.8 %
|
|
Percent Air Voids 2
|
3.9 %
|
|
Percent Air Voids 3
|
4.1 %
|
|
Average Percent Air Voids
|
3.9 %
|
DIME Test ID: 2023-10-09-30-3
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/26/2023
Date Tested: 10/10/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=5.49%
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3016.2 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4589.1 g
|
|
Mass of HMA Sample prior to ignition
|
1572.9 g
|
|
Corrected Asphalt Binder Content
|
5.49 %
|
|
Mass Loss
|
101.1 g
|
|
Mass of aggregate remaining after ignition
|
1471.8 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.75 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.19 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2023-10-09-30-5
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 10/26/2023
Date Tested: 10/11/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmb=2.404
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.408
|
|
Bulk Specific Gravity 2
|
2.405
|
|
Bulk Specific Gravity 3
|
2.4
|
|
Average Bulk Specific Gravity
|
2.404
|
DIME Test ID: 2023-10-09-30-6
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/26/2023
Date Tested: 10/17/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmm=2.503
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7335.1 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1585.7 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8287.3 grams
|
|
Temperature of Water
|
24 °F
|
|
Specific Gravity for Sample 1
|
2.503
|
|
Theoretical maximum density at 25°C (77°F)
|
2495.7 kg/m^3
|