2023-09-01-58-1 | CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete | 10/12/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Richmond Field Laboratory | Beam Set 4
Beam FAILED
Vanguard Mobile Hercules Plant | |
2023-09-01-58-2 | CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete | 10/12/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Richmond Field Laboratory | Beam Set 5
1 Beam FAILED and other PASSED
Vanguard Mobile Hercules Plant
2nd beam is broken at 12 Hours | |
2023-09-01-58-3 | CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete | 10/12/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Richmond Field Laboratory | Beams PASSED
Vanguard Mobile Hercules Plant | |
2023-09-01-58-4 | CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete | 10/12/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Richmond Field Laboratory | Beam Set PASSED
Vanguard Mobile Hercules Plant | |
2023-09-01-58-5 | CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete | 10/12/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Richmond Field Laboratory | Beam Set 7
Beams FAILED
Vanguard Mobile Hercules Plant
2nd Beam Broke at 10 Hours | |
2023-09-01-58-6 | CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete | 10/12/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Richmond Field Laboratory | Beam Set 6
Beam PASSED
Vanguard Mobile Hercules Plant | |
2023-09-01-58-7 | CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete | 10/12/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Richmond Field Laboratory | Beam Set 6
1 Beam Failed
Other PASSED
Vanguard Mobile Hercules Plant
2nd Beam Broke at 10 Hours | |
2023-09-01-58-8 | CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete | 10/12/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Richmond Field Laboratory | Beam Set 2 C
Beams PASSED
Vanguard Mobile Hercules Plant C | |
2023-09-01-58-9 | CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete | 10/12/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Richmond Field Laboratory | Beam Set 3 A
Beams PASSED
Vanguard Mobile Hercules Plant A | |
2023-09-01-58-10 | CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete | 10/12/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Richmond Field Laboratory | Beam Set 4 B
Beams PASSED
Vanguard Mobile Hercules Plant B | |
2023-09-01-58-11 | CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete | 10/12/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Richmond Field Laboratory | Beam Set 7 B
Beams PASSED
Vanguard Mobile Hercules Plant B | |