Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994616 DEA: 112N1654 EFIS: 1122000152
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-8-R61.0/R68.0
Work Description: PLACE RHMA-G(BWC) OVERLAY, PAVEMENT MARKING, & RUMBLE STRIP.
Location Description: SAN DIEGO COUNTY NEAR BOULEVARD FROM 0.1 MILE WEST OF CRESTWOOD ROAD UNDERCROSSING TO 0.2 MILE EAST OF MCCAIN VALLEY ROAD UNDERCROSSING
Contractor Name: MARTIN MARIETTA SAN DIEGO AGGREGATES LLC DBA ATP GENERAL ENGINEERING CONTRACTORS
Contractor Address: 4211 Ponderosa Ave. Suite C, San Diego, CA 92123
Resident Engineer: Fahad Masud Structure Rep.: Unknown
DIME Sample ID: 2023-10-10-33
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/10/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/10/2023
The quantity of what the sample constitutes: 12 boxes 2 bags
A brief description of the sample: 1/2" RHMA-A
From where was the sample collected: Source
Laboratory sample identification: 9701-PSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marrieta
DIME Test ID: 2023-10-10-33-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 11/06/2023
Date Tested: 10/24/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Binder Target number - 7.5
Passed with 7.4
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3991.7 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5580 g
|
|
Mass of HMA Sample prior to ignition
|
1588.3 g
|
|
Corrected Asphalt Binder Content
|
7.42 %
|
|
Mass Loss
|
120.8 g
|
|
Mass of aggregate remaining after ignition
|
1467.5 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.19 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 F
|
DIME Test ID: 2023-10-10-33-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 11/06/2023
Date Tested: 10/24/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7477.1 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1553.8 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8395.5 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.445
|
|
Theoretical maximum density at 25°C (77°F)
|
152.2 lb/ft^3
|
DIME Test ID: 2023-10-10-33-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 11/06/2023
Date Tested: 10/24/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Voids Failed Height Requirement of 115.0 mm
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Bulk Specific Gravity
|
no data0
|
|
Bulk Specific Gravity 2
|
no data0
|
|
Bulk Specific Gravity 3
|
no data0
|
|
Average Bulk Specific Gravity
|
no data0
|
DIME Test ID: 2023-10-10-33-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 11/06/2023
Date Tested: 10/24/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Air Voids Failed the Height Requirement of 115 mm
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Percent Air Voids
|
100 %
|
|
Percent Air Voids 2
|
100 %
|
|
Percent Air Voids 3
|
100 %
|
|
Average Percent Air Voids
|
100 %
|
DIME Test ID: 2023-10-10-33-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 11/06/2023
Date Tested: 10/25/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Average Dry Tensile Strength
|
307 psi
|
|
Average Wet Tensile Strength
|
240 psi
|
|
Tensile Strength Ratio
|
0.78
|
DIME Test ID: 2023-10-10-33-6
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 11/06/2023
Date Tested: 10/31/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Max 12.00 mm
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
no data
|
|
Test Temperature
|
122 F
|
|
Air Void Content for specimen A-1
|
no data
|
|
Air Void Content for specimen A-2
|
no data
|
|
Air Void Content for specimen B-1
|
no data
|
|
Air Void Content for specimen B-2
|
no data
|
|
Stripping Inflection Point (Wheel A)
|
>20000
|
|
Stripping Inflection Point (Wheel B)
|
>20000
|
|
Maximum impression at 5000 passes (left wheel)
|
2.45 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
1.83 mm
|
|
Average impression at 5000 passes (left/right avg)
|
2.14 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
3.17 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
2.17 mm
|
|
Average impression at 10000 passes (left/right avg)
|
2.67 mm
|
|
Maximum impression at 15000 passes (left wheel)
|
4.23 mm
|
|
Maximum impression at 15000 passes (right wheel)
|
2.59 mm
|
|
Average impression at 15000 passes (left/right avg)
|
3.41 mm
|
|
Maximum impression at 20000 passes (left wheel)
|
9.43 mm
|
|
Maximum impression at 20000 passes (right wheel)
|
3.32 mm
|
|
Average impression at 20000 passes (left/right avg)
|
6.38 mm
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|
DIME Test ID: 2023-10-10-33-7
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 01/23/2024
Date Tested: 01/24/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Retest
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.276
|
|
Bulk Specific Gravity 2
|
2.277
|
|
Bulk Specific Gravity 3
|
2.278
|
|
Average Bulk Specific Gravity
|
2.277
|
DIME Test ID: 2023-10-10-33-8
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 01/23/2024
Date Tested: 01/24/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: FAIL
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Percent Air Voids
|
6.9 %
|
|
Percent Air Voids 2
|
6.9 %
|
|
Percent Air Voids 3
|
6.8 %
|
|
Average Percent Air Voids
|
6.9 %
|