Print Report | Back to Sample Detail

Sample Record for 2023-09-26-51

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994685 DEA: 043Q6104 EFIS: 0419000229 QA Service Level: 1
DIST-CO-RTE-PM: 04-SCL-17,85,87,101-Var
Work Description: POLYESTER CONCRETE OVERLAY, AND STRUCTURAL CONCRETE APPROACH SLAB.
Location Description: SANTA CLARA COUNTY AT VARIOUS LOCATIONS
Contractor Name: TRUESDELL CORPORATION OF CALIFORNIA, INC
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-09-26-51
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Methacrylate
Sample Taken Date: 09/26/2023
Date that the sample was received by the laboratory/organization performing the testing: 09/27/2023
The quantity of what the sample constitutes: 100 Totes
A brief description of the sample: 2 pints 204,chp,,8020
From where was the sample collected: Source
Laboratory sample identification: 000018KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia

Material Information

Mfg. Lot Number(s): 2390691790
Batch number: 2390691790
Mix number: 2390691790

Test Results

Test 1 of 1

DIME Test ID: 2023-09-26-51-1
Test Method: CONCLP 4-16: HMWM
Verified Date: 11/03/2023
Date Tested: 10/19/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: CTM 551 & ASTM C 679 - accepted vendor's results
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F 21
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F 1.08
Volatile content (ASTM D 2369) 30% max 10
Flash point (ASTM D 3828) more than 180 deg F 200
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours 891
Tack free time, 400 minutes max 380